The AirTAC GC FRL Unit GC200C08C1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC200C08C1 is an AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied as one matched set for compressed-air preparation. This configuration is size 200 with 1/4" PT ports, a 40 um standard filter element, a differential-pressure drain on the filter bowl, and a round pressure gauge reading in MPa. In service the filter removes water and particulate, the regulator holds a steady downstream pressure adjustable from 0.15 to 0.9 MPa (20-130 psi) with the differential-pressure drain fitted, and the lubricator feeds an oil mist to downstream tools and actuators. Maximum working pressure is 1.0 MPa (145 psi); working temperature range is -5 to 70 C (non-freezing). The 200-size bowls are polycarbonate (PC).
This is a genuine AirTAC part. The G-series F.R.L. line spans sizes 200, 300, 400 and 600 with ports from 1/8" to 1", PT (standard), G (BSPP) and NPT threads, 40 um standard or 5 um filtration, automatic or manual drains in place of the differential-pressure drain, and MPa, psi or bar gauge scales. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures on request before you order.
| Model | Airtac GC FRL Unit GC200C08C1 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Clean, regulated and lubricated air feeding the pneumatic clamp cylinders and tool-change actuators on a CNC machining center, where steady holding pressure protects part position through the cycle.
Air preparation for the flap-fold and tape-head cylinders of a carton sealing conveyor, keeping actuator pressure consistent from the first box of a shift to the last.
A filtered, regulated and oil-mist lubricated drop at an assembly workstation running impact wrenches and ratchets, so tools receive clean air at a set pressure with continuous lubrication.
Size 200 with 1/4" PT ports is the entry step of the G-series; step up to 300, 400 or 600 for larger ports and higher air demand. This set uses the differential-pressure drain, giving a 0.15-0.9 MPa (20-130 psi) regulator range; automatic (A) or manual (M) drains can be ordered instead, and the manual-drain versions widen the range to 0.05-0.9 MPa (7-130 psi). Filtration is the 40 um standard element; the W option gives 5 um where finer cleaning is needed. The gauge here is round with an MPa scale; psi or bar scales and the square gauge are orderable. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the G-series as performance curves rather than a single rated figure, so we do not quote one number here. Tell us your line pressure and air demand and we will confirm the flow from the datasheet curve for this exact model before you order.
The differential-pressure drain is the standard fitting: it bleeds condensate from the filter bowl when the pressure differential across the bowl rises as liquid collects. If you prefer, the GC200 series can be ordered with an automatic drain (code A) or a manual drain (code M); note that manual-drain sets carry a 0.05-0.9 MPa (7-130 psi) regulator range versus 0.15-0.9 MPa (20-130 psi) with the differential-pressure drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.