The AirTAC GC FRL Unit GC200C08C1K is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC200C08C1K is an AirTAC G-series three-unit F.R.L. combination - separate filter, regulator and lubricator in one matched set - with the K option, meaning a reverse (check) valve is fitted. This configuration is size 200 with 1/4" PT ports, a 40 um standard filter element, a differential-pressure drain on the filter bowl, and a round pressure gauge reading in MPa. The regulator holds a steady downstream pressure adjustable from 0.15 to 0.9 MPa (20-130 psi) with the differential-pressure drain, and the lubricator feeds an oil mist to downstream tools and actuators. Maximum working pressure is 1.0 MPa (145 psi); working temperature range is -5 to 70 C (non-freezing). The 200-size bowls are polycarbonate (PC).
This is a genuine AirTAC part. The G-series F.R.L. line spans sizes 200, 300, 400 and 600 with ports from 1/8" to 1", PT (standard), G (BSPP) and NPT threads, 40 um standard or 5 um filtration, automatic or manual drains in place of the differential-pressure drain, and MPa, psi or bar gauge scales. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures on request before you order.
| Model | Airtac GC FRL Unit GC200C08C1K |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Regulated, filtered and lubricated air to the clamp cylinders of a press-fit assembly fixture, where the fitted check valve is specified in the station's air-preparation stack.
Air preparation for the pusher and gating cylinders on a bottling conveyor, delivering clean air at a set pressure with oil mist for the actuators along the line.
A point-of-use F.R.L. station at maintenance shop benches running pneumatic tools, with the K configuration specified where the circuit calls for a reverse (check) valve.
Size 200 with 1/4" PT ports is the entry step of the G-series; move to 300, 400 or 600 for larger ports and higher air demand. This set adds the K reverse (check) valve and uses the differential-pressure drain, giving a 0.15-0.9 MPa (20-130 psi) regulator range; automatic (A) or manual (M) drains are orderable, with manual drain widening the range to 0.05-0.9 MPa (7-130 psi). Filtration is the 40 um standard element, with 5 um available as the W option. The gauge is round with an MPa scale; psi or bar scales and the square gauge are catalogue choices. Thread is PT standard, with G (BSPP) and NPT orderable. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes G-series flow as performance curves rather than a single rated figure, so we do not quote one number here. Send us your supply pressure and air demand and we will confirm the flow from the datasheet curve for this exact model, check valve included, before you order.
K is the AirTAC code for a reverse (check) valve fitted in the unit. The rest of the code decodes as a size 200 three-unit F.R.L. with 1/4" PT ports, 40 um standard filtration, differential-pressure drain and a round MPa gauge. If your circuit does not call for a check valve, the same set is available without it as GC200C08C1.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.