verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC200C08F1

The AirTAC GC FRL Unit GC200C08F1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$71.79 $77.26Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C08F1

GC200C08F1 is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set. This configuration is size 200 with PT1/4 (PT thread) ports, the standard 40 um filter element, a differential-pressure drain on the filter bowl, and an embedded square pressure gauge scaled in MPa. The filter and lubricator bowls are polycarbonate at this size. The set handles compressed air from -5 to 70 C (non-freezing) at up to 1.0 MPa (145 psi) inlet, and with the differential-pressure drain the regulator adjusts over 0.15-0.9 MPa (20-130 psi).

This is a genuine AirTAC part. The GC combination is offered in 200, 300, 400 and 600 sizes with ports from 1/8 in. to 1 in., a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filtration, round or square gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow figures are published as curves rather than a single rating, so ask us and we will confirm the datasheet numbers for this model on request.

Airtac GC FRL Unit GC200C08F1 Technical Specifications

ModelAirtac GC FRL Unit GC200C08F1
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C08F1

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C08F1 Is Used

conveyor_belt

Bottling line conveyor air

Conditioning the air feeding guide-rail clamps and stop-gate cylinders along a bottling conveyor, with filter, regulation and oil mist handled in one mounted set.

build

Assembly bench torque tools

Air preparation for pneumatic screwdrivers and nutrunners on a small assembly bench, keeping the regulators and valves of the tools supplied with clean, lubricated air.

factory

Packaging machine actuation

Supplying the sealing-jaw and vacuum-generator circuits on a horizontal form-fill-seal machine, where one F.R.L. point protects every downstream actuator on the frame.

Is the Airtac GC FRL Unit GC200C08F1 the Right Station?

Size 200 with PT1/4 ports suits compact manifolds and machine frames; move to 300, 400 or 600 when larger ports and more flow are needed. The filter drain comes as differential-pressure here, with automatic and manual options available. Filtration is the 40 um standard element; order the W suffix for 5 um where downstream components need finer protection. This set carries the embedded square gauge with an MPa scale; the round external gauge with MPa, psi or bar scales is the alternative. Thread is PT as standard, with G (BSPP) and NPT available as order options. Because flow is published as curves rather than a single rating, ask us to confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C08F1 FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so no one number covers every condition. Tell us your working pressure and required air consumption and we will confirm the GC200C08F1 datasheet curve values on request before you order.

The GC is filter plus regulator plus lubricator, so it also delivers oil mist to downstream air tools and cylinders. The two-unit GFC set covers only filter, regulation and lubrication split across a filter-regulator and lubricator; choose GC when the actuators on the circuit need lubrication as well as clean, regulated air.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C08F1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08F1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.