The AirTAC GC FRL Unit GC200C08F1K is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC200C08F1K is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set, with the K suffix adding a reverse (check) valve to the regulator section. This configuration is size 200 with PT1/4 (PT thread) ports, the standard 40 um filter element, a differential-pressure drain on the filter bowl, and an embedded square pressure gauge scaled in MPa. The bowls are polycarbonate at this size. The set handles compressed air from -5 to 70 C (non-freezing) at up to 1.0 MPa (145 psi) inlet, and with the differential-pressure drain the regulator adjusts over 0.15-0.9 MPa (20-130 psi).
This is a genuine AirTAC part. The GC combination is offered in 200, 300, 400 and 600 sizes with ports from 1/8 in. to 1 in., differential-pressure, automatic or manual drains, 40 um or 5 um filtration, round or square gauges with MPa, psi or bar scales, PT, G or NPT threads, and the check-valve option fitted on this model. Flow figures are published as curves rather than a single rating, so ask us and we will confirm the datasheet numbers on request.
| Model | Airtac GC FRL Unit GC200C08F1K |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Air preparation for a fixture-clamping manifold where the fitted check valve helps hold the regulated downstream circuit while the compressor cycles or the main supply dips.
A benchtop F.R.L. point at a maintenance shop air drop, giving technicians filtered, regulated, lubricated air for impact tools, blow guns and test rigs off one connection.
Supplying the capstan and dancer-roller actuation circuits on wire-drawing and cable-spooling machinery, with clean regulated air set to the actuator working pressure.
Size 200 with PT1/4 ports is the compact G-series step; step to 300, 400 or 600 for larger ports and more flow. The K suffix fits a reverse (check) valve, the right choice when you want the downstream circuit held if upstream supply dips. The drain on this set is differential-pressure; automatic and manual drains can be ordered instead. Filtration is 40 um standard with the 5 um W suffix available. The gauge is the embedded square type with an MPa scale. Thread is PT as standard, with G (BSPP) and NPT as order options. Flow is published as curves, not a single rated figure, so send your line pressure and demand and we will confirm datasheet sizing before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
There is no single rated flow figure: AirTAC publishes G-series performance as curves across pressure and port size. Send us your working pressure and air consumption and we will confirm the GC200C08F1K datasheet figures on request before you order.
K indicates that a reverse (check) valve is fitted in the regulator section. The standard GC200C08F1 without the K has no check valve. Choose the K version where you want the downstream side held against a temporary upstream pressure loss.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.