The AirTAC GC FRL Unit GC200C08F1W is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC200C08F1W is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set, with the W suffix specifying the finer 5 um filter element. This configuration is size 200 with PT1/4 (PT thread) ports, a differential-pressure drain on the filter bowl, and an embedded square pressure gauge scaled in MPa. The filter and lubricator bowls are polycarbonate at this size. The set handles compressed air from -5 to 70 C (non-freezing) at up to 1.0 MPa (145 psi) inlet, and with the differential-pressure drain the regulator adjusts over 0.15-0.9 MPa (20-130 psi).
This is a genuine AirTAC part. The GC combination is offered in 200, 300, 400 and 600 sizes with ports from 1/8 in. to 1 in., differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) filtration, round or square gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow figures are published as curves rather than a single rating, so ask us and we will confirm the datasheet numbers for this model on request.
| Model | Airtac GC FRL Unit GC200C08F1W |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Supplying the atomizing air and gun-actuation circuit at a paint spray booth, where the 5 um element supports a cleaner air supply for coating work.
Conditioning the air feeding compact pick-and-place modules with small pilot valves and vacuum ejectors, where fine filtration helps keep narrow valve passages clear.
Air preparation on an engineering test rig supplying reference actuators and pneumatic instrumentation, with regulation set from the MPa-scale gauge on the set.
Size 200 with PT1/4 ports is the compact step of the G-series; go to 300, 400 or 600 for larger ports and more flow. The W suffix here fits the 5 um element instead of the 40 um standard, the choice when downstream valves, cylinders or process equipment need finer particulate removal. The drain is differential-pressure, with automatic and manual options available. The gauge is the embedded square type with an MPa scale; the round external gauge in MPa, psi or bar is the alternative. Thread is PT as standard, with G (BSPP) and NPT as order options. Because flow is published as curves rather than a single rating, ask us to confirm datasheet sizing against your application before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes G-series flow as curves across pressure and port size, not as a single rated number, so we do not state one here. Send us your line pressure and air demand and we will confirm the GC200C08F1W datasheet figures on request before you order.
The W suffix fits the 5 um element for applications where finer particulate removal matters, such as coating, instrumentation or compact valving. The standard 40 um element suits general plant air. Both are available across the GC range, so choose by what the downstream equipment needs.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.