AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC200C08F1WK

The AirTAC GC FRL Unit GC200C08F1WK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$83.14 $88.88Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C08F1WK

The GC200C08F1WK is a genuine three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and lubricator, in the 200 size with PT1/4 ports. The filter carries the finer 5 um (W) element, the bowl drains by differential pressure (the catalogue default), and the regulator is fitted with an embedded square gauge reading in MPa. A reverse (check) valve (K) is also fitted in this configuration. With the differential-pressure drain the regulator adjustment range is 0.15-0.9 MPa (20-130 psi). Maximum inlet pressure is 1.0 MPa (145 psi), bowls in the 200 size are polycarbonate, and the working temperature range is -5 to 70 C, non-freezing, on compressed air only.

This is a genuine AirTAC part from airtacdistr.com. The GC series is offered in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, plus options for manual or automatic drains, 40 um or 5 um elements, gauge scale, and G or NPT threads in place of the PT standard. Because AirTAC publishes flow only as curves, we confirm datasheet figures for this exact configuration on request.

Airtac GC FRL Unit GC200C08F1WK Technical Specifications

ModelAirtac GC FRL Unit GC200C08F1WK
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C08F1WK

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C08F1WK Is Used

precision_manufacturing

CNC tool-clamping circuit

Feeds the 5 um-filtered, regulated and lubricated air that acts the spindle drawbar and tool-clamping cylinders on a machining centre, protecting the clamping valve from water and chips in the line.

conveyor_belt

Carton sealing line

Prepares the supply for the pneumatic cylinders that fold, press and seal cartons on a packaging conveyor, with the check valve helping the circuit hold its set pressure at the cylinders.

air

Automotive refinish spray booth

Conditions booth air ahead of HVLP spray guns: the 5 um element keeps water and fine particulate out of the finish, while the lubricator mists oil to the gun trigger valve and air tools.

Is the Airtac GC FRL Unit GC200C08F1WK the Right Station?

Choose the size and port step (200/300/400/600, ports 1/8 to 1 in) against the air your circuit actually uses, then set drain type: differential-pressure is the default here, while automatic (A) and manual (M) drains can be ordered instead. Element grade is 5 um on this unit versus the 40 um standard, the square gauge reads in MPa (psi and bar scales are available), and thread is PT as standard with G (BSPP) and NPT as orderable options. A mounting bracket can be specified.

Flow for the G series is published as curves, not a single rated figure, so ask us to confirm sizing for this configuration against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C08F1WK FAQ

AirTAC publishes flow for the G series as curves rather than a single rated number, so we do not quote a figure on this page. Ask us and we will confirm the flow data for this exact configuration from the datasheet so you can size it against your application.

The blank drain position in the code is the catalogue default: a differential-pressure drain. Automatic (A) and manual (M) drains are available as options. Note the regulator range also follows the drain type: 0.15-0.9 MPa (20-130 psi) with the differential-pressure drain, 0.05-0.9 MPa (7-130 psi) with a manual drain.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C08F1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08F1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.