verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC200C08MC1K

The AirTAC GC FRL Unit GC200C08MC1K is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$83.14 $88.88Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C08MC1K

The GC200C08MC1K is a genuine three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and lubricator, in the 200 size with PT1/4 ports. The filter uses the standard 40 um element, the bowl is drained manually, and the regulator carries an external round gauge reading in MPa. The K in the code means a reverse (check) valve is fitted in this configuration. With the manual drain the regulator adjustment range is 0.05-0.9 MPa (7-130 psi). Maximum inlet pressure is 1.0 MPa (145 psi), bowls in the 200 size are polycarbonate, and the working temperature range is -5 to 70 C, non-freezing, on compressed air only.

This is a genuine AirTAC part from airtacdistr.com. The GC series spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, plus options for automatic or differential-pressure drains, 5 um elements, gauge scale and thread, and the check valve itself can be omitted (blank) or fitted (K) when ordering. Because AirTAC publishes flow only as curves, we confirm datasheet figures for this exact configuration on request.

Airtac GC FRL Unit GC200C08MC1K Technical Specifications

ModelAirtac GC FRL Unit GC200C08MC1K
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C08MC1K

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C08MC1K Is Used

handyman

Maintenance workshop bench

A general-purpose prep set at the maintenance bench: filtered, regulated and lubricated air for grinders, drills and blow guns, with the manual drain emptied as part of weekly upkeep.

precision_manufacturing

Mould ejection circuit

Supplies the pneumatic ejector and core-pull cylinders on an injection moulding tool, where the fitted check valve is part of the catalogue configuration for circuits that must not vent back through the prep set.

engineering

Pick-and-place gripper supply

Conditions air for the gripper and vacuum-generator manifold on a pick-and-place cell, with the regulator set at the panel and the round MPa gauge giving operators a visible setpoint.

Is the Airtac GC FRL Unit GC200C08MC1K the Right Station?

Size and port come first: 200/300/400/600 with ports from 1/8 to 1 in, matched to the air your circuit actually uses. Drain type is your next choice - this unit is manual, giving the 0.05-0.9 MPa (7-130 psi) regulation range, while automatic and differential-pressure drains are orderable. The 40 um element here is the standard grade; the 5 um W element suits finer applications. The K option adds the reverse (check) valve fitted on this unit. Thread is PT as standard, with G (BSPP) and NPT as catalogue options.

Flow is published as curves rather than a single rated number, so ask us to check this configuration against your application's demand before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C08MC1K FAQ

Yes. AirTAC publishes G-series flow as curves rather than a single rated figure, which is why no flow number appears on this page. Send us your application details and we will confirm the flow data for this exact configuration from the datasheet.

K is the reverse (check) valve option for this family: fitted on this unit, absent (blank) when not ordered. Everything else decodes as the standard GC three-unit set - 200 size, PT1/4, manual drain, 40 um element and round MPa gauge.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C08MC1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08MC1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.