The AirTAC GC FRL Unit GC200C08MF1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one set, so a single supply drop gets water and particle removal, regulated pressure and mist lubrication in one stop. This GC200C08MF1 is the 200 size set with 1/4 in PT ports, a manual-drain filter bowl, the standard 40 um filter element and an embedded square pressure gauge reading in MPa. All bowls are polycarbonate at this size, the set runs on compressed air at up to 1.0 MPa (145 psi) inlet and -5 to 70 C (non-freezing), and with the manual drain the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi).
This is a genuine AirTAC part. The G-series combination sets run from 200 through 600 sizes with ports from 1/8 in to 1 in, and can be ordered with manual, automatic or differential-pressure drains, 40 um or 5 um filtration, square or round gauges in MPa, psi or bar scales, a check valve, and PT, G (BSPP) or NPT threads. AirTAC publishes flow for this series as pressure-drop curves rather than a single rated figure, so ask us for the datasheet and we will confirm the figures for your application on request.
| Model | Airtac GC FRL Unit GC200C08MF1 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Supplies the seal and clamp cylinders with regulated, oil-misted air; the square MPa gauge lets operators set and check line pressure at a glance.
Powers swing clamps on a weld fixture, with the 40 um filter catching pipe scale and the lubricator conditioning the clamp cylinders.
A tidy F.R.L. at the bench drop for impact drivers and ratchets: filtered air, a set pressure and a continuous oil mist for the tools.
The 200 size with 1/4 in PT ports is the entry step of the G-series range; if your demand is beyond what the 200-size bodies pass, step up to 300 (3/8-1/2 in), 400 (1/2-3/4 in) or 600 (1 in). This set carries a manual drain, so the regulator spans 0.05-0.9 MPa (7-130 psi) and the bowl is drained by hand; the standard element is 40 um, and a 5 um element is available in the same size if you need finer filtration. The embedded square gauge reads MPa, with psi or bar scales orderable. PT is the standard thread, with G (BSPP) and NPT available as orderable options. AirTAC publishes flow as pressure-drop curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes G-series flow as pressure-drop curves rather than a single rated figure, so we do not quote one number. Send us your line pressure and expected air demand and we will confirm the sizing from the datasheet on request.
With a manual drain the regulator adjustment span is the wider 0.05-0.9 MPa (7-130 psi), and you drain the filter bowl by hand; automatic or differential-pressure drain versions are adjusted from 0.15-0.9 MPa (20-130 psi). The GC200C08MF1 is the manual-drain version.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.