AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC200C08MF1K

The AirTAC GC FRL Unit GC200C08MF1K is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$83.14 $88.88Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C08MF1K

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one set, so a single supply drop gets water and particle removal, regulated pressure and mist lubrication in one stop. This GC200C08MF1K is the 200 size set with 1/4 in PT ports, a manual-drain filter bowl, the standard 40 um filter element, an embedded square pressure gauge reading in MPa and a fitted reverse (check) valve. All bowls are polycarbonate at this size, the set runs on compressed air at up to 1.0 MPa (145 psi) inlet and -5 to 70 C (non-freezing), and with the manual drain the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi).

This is a genuine AirTAC part. The G-series combination sets run from 200 through 600 sizes with ports from 1/8 in to 1 in, and can be ordered with manual, automatic or differential-pressure drains, 40 um or 5 um filtration, square or round gauges in MPa, psi or bar scales, a check valve, and PT, G (BSPP) or NPT threads. AirTAC publishes flow for this series as pressure-drop curves rather than a single rated figure, so ask us for the datasheet and we will confirm the figures for your application on request.

Airtac GC FRL Unit GC200C08MF1K Technical Specifications

ModelAirtac GC FRL Unit GC200C08MF1K
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C08MF1K

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C08MF1K Is Used

factory

Stamping press auxiliaries

Feeds part blow-off and ejector cylinders on a stamping line; the check valve holds the downstream side against backflow when the main supply cycles.

build

Assembly screwdriver station

Conditions air for pneumatic screwdrivers and nutrunners at a workstation, with regulated pressure and continuous oil mist for the tool motors.

valve

Actuated valve panel

Supplies quarter-turn valve actuators on a process skid with clean, lubricated air, while the check valve blocks any reverse flow toward the set.

Is the Airtac GC FRL Unit GC200C08MF1K the Right Station?

The 200 size with 1/4 in PT ports is the entry step of the G-series range; if your demand is beyond what the 200-size bodies pass, step up to 300 (3/8-1/2 in), 400 (1/2-3/4 in) or 600 (1 in). This set carries a manual drain, so the regulator spans 0.05-0.9 MPa (7-130 psi) and the bowl is drained by hand; the standard element is 40 um, with a 5 um element orderable in the same size. The K code adds the reverse (check) valve, and the embedded square gauge reads MPa, with psi or bar scales orderable. PT is the standard thread, with G (BSPP) and NPT available as orderable options. AirTAC publishes flow as pressure-drop curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C08MF1K FAQ

AirTAC publishes G-series flow as pressure-drop curves rather than a single rated figure, so we do not quote one number. Send us your line pressure and expected air demand and we will confirm the sizing from the datasheet on request.

The F1 suffix decodes to the embedded square pressure gauge reading in MPa. A round external gauge is also offered in the series, and psi or bar scales can be ordered in the same code position.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C08MF1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08MF1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.