AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC200C08MN

The AirTAC GC FRL Unit GC200C08MN is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$66.14 $71.46Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C08MN

The AirTAC GC series is a three-unit F.R.L. combination: separate filter, regulator and lubricator assembled as one set. This GC200C08MN is the 200 size with PT1/4 ports, a manual-drain filter bowl and the standard 40 um filter element. It removes water and particulate, regulates downstream pressure, and meters oil mist to air tools and cylinders. No gauge is fitted (N), so downstream pressure is set and checked with your own gauge.

This is a genuine AirTAC part. Maximum working pressure is 1.0 MPa (145 psi), the manual-drain regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), and the temperature range is -5 to 70 C, non-freezing. The 200-size bowl is polycarbonate (PC). AirTAC publishes flow as curves rather than a single rated figure, so contact us and we will confirm flow and datasheet figures for your application on request.

Airtac GC FRL Unit GC200C08MN Technical Specifications

ModelAirtac GC FRL Unit GC200C08MN
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C08MN

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C08MN Is Used

handyman

Workshop air-tool drop

Installed at a maintenance-bench air drop to feed impact wrenches, ratchets and grinders: the filter strips water from the main line, the regulator caps tool pressure, and the lubricator keeps the tool vanes oiled.

conveyor_belt

Carton-sealing machine supply

Prepares air for the clamp and taping cylinders of a carton sealer on a packing line, combining water removal, a set operating pressure and light oiling so the cylinders keep cycling smoothly.

factory

Assembly-line air cylinders

Feeds the small air cylinders on an assembly workstation where a separate panel gauge already reads line pressure, providing clean, regulated, lubricated air without duplicating instrumentation.

Is the Airtac GC FRL Unit GC200C08MN the Right Station?

Size 200 with 1/4 in (08) PT ports is the compact step of the G series; move up to 300, 400 or 600 if your demand exceeds a 1/4 in line. The manual drain means periodic hand-draining of the bowl; automatic and differential-pressure drain variants are available. The element is the standard 40 um grade; choose the W variant for 5 um fine filtration. This code carries no gauge (N); versions with an embedded square gauge or external round gauge exist if you want a local pressure readout. Thread is PT as standard, with G (BSPP) and NPT as orderable options, and a bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C08MN FAQ

AirTAC publishes flow for the G series as curves rather than a single rated figure, so we do not state a rated flow number. Share your pressure and air-demand details and we will confirm the flow and datasheet figures for this unit on request.

The N suffix means no gauge is fitted, so you set the regulator with a screwdriver and read pressure on your own downstream gauge. If you prefer a local readout, the same 200-size combination is available with an embedded square gauge or an external round gauge in MPa, psi or bar scales.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C08MN

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08MN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.