The AirTAC GC FRL Unit GC200C08MNWK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200C08MNWK is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and lubricator, each doing one job, assembled at size 200 with PT1/4 (1/4 in) ports. This configuration carries the 5 um filter element, a manual drain on the filter bowl and a reverse (check) valve, and it is supplied without a pressure gauge. The regulator adjusts from 0.05-0.9 MPa (7-130 psi) on this manual-drain build, maximum inlet pressure is 1.0 MPa (145 psi), and the filter and lubricator bowls are polycarbonate (PC) at this size.
It is a genuine AirTAC part for compressed air, rated -5 to 70 C (non-freezing). The G-series combination range steps from size 200 to 600, with 40 um or 5 um filtration, differential-pressure, automatic or manual drains, embedded square or external round gauges, and PT as the standard thread with G (BSPP) and NPT available to order. Flow is published as curves rather than a single rating, so we confirm the datasheet figures on request before you order.
| Model | Airtac GC FRL Unit GC200C08MNWK |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Conditions the air feeding the gripper cylinders of a case palletizer. The check valve holds the downstream circuit if the supply line is opened or dropped, so a stacked layer is not released mid-move.
Feeds the sealing-jaw and product-push cylinders of a VFFS packaging machine: 5 um filtration ahead of the control valves, a set regulator pressure for repeatable jaw closing, and oil mist for the cylinders.
Runs impact wrenches, dual-action sanders and cut-off tools in an auto refinishing bay at a set pressure, with oil mist carried to the tools and water and debris removed by the 5 um element. The manual drain suits a bay bled down at shift end.
Size 200 is the smallest step of the G-series combination range; step to 300, 400 or 600 when the connected demand outgrows the PT1/4 port. Keep the manual drain only where an operator can bleed the bowl routinely - automatic draining suits unattended cells. The fitted check valve is worth keeping where clamps, grippers or lifts must hold their state if the supply is isolated, and the 5 um element protects finer valves than the 40 um standard would. Thread is PT as standard, with G (BSPP) and NPT as catalogue options, and an optional bracket is available for mounting. Because AirTAC publishes flow as curves rather than one rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes G-series flow as curves, not as a single rated figure, so no rated flow number is quoted here. Send us your inlet pressure and the equipment you plan to feed and we will confirm the sizing and datasheet figures on request.
M in the code selects a manual-drain filter bowl: collected water is bled by hand, which suits a cell that is shut down and drained regularly. The differential-pressure drain is the default and an automatic drain is a catalogue option. With the manual build the regulator adjusts from 0.05-0.9 MPa (7-130 psi), against 0.15-0.9 MPa (20-130 psi) on the automatic and differential-pressure drains.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.