The AirTAC GC FRL Unit GC200C08N is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200C08N is a three-piece AirTAC G-series F.R.L. combination: separate air filter, pressure regulator and lubricator, mounted at size 200 on PT1/4 (1/4 in) ports. It keeps the standard 40 um element and the default differential-pressure drain, has no reverse valve, and is supplied without a gauge; the regulator adjusts from 0.15-0.9 MPa (20-130 psi). Maximum inlet pressure is 1.0 MPa (145 psi), and the filter and lubricator bowls are polycarbonate (PC) at this size.
It is a genuine AirTAC part for compressed air, rated -5 to 70 C (non-freezing). The G-series combination range steps from size 200 to 600, with 40 um or 5 um filtration, differential-pressure, automatic or manual drains, embedded square or external round gauges, and PT as the standard thread with G (BSPP) and NPT available to order. Flow is published as curves rather than a single rating, so we confirm the datasheet figures on request before you order.
| Model | Airtac GC FRL Unit GC200C08N |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Supplies the clamp and swing cylinders on a small-parts assembly bench: 40 um filtration for standard valving, regulated pressure for consistent clamping, and oil mist for the cylinders.
Conditions the air to the divert and stopper gates along a distribution conveyor, keeping the directional valves fed with filtered, lubricated air at a fixed setting.
Feeds the actuated fixtures on a PLC-controlled leak or assembly test station where a fixed, lubricated supply is needed and no local gauge readout is required.
Size 200 with PT1/4 ports is the entry step; the 300, 400 and 600 sizes raise the port and the air demand they suit. The differential-pressure drain is the default and needs no routine attention while air is flowing; automatic or manual draining are catalogue options. The standard 40 um element is right for general valves and cylinders, and the W build with 5 um is there when finer protection is needed. No gauge is fitted, but embedded square and external round gauge builds are orderable, and the thread is PT as standard with G (BSPP) and NPT to order. Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
Flow for the G-series is published as curves rather than one rated number, so we do not state a rated flow here. Tell us your application and inlet pressure and we will confirm the sizing from the datasheet on request.
Yes. N means this build is supplied without a gauge. AirTAC offers the combination with an embedded square gauge or an external round gauge as catalogue options; tell us which readout you want and we will quote that build.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.