The AirTAC GC FRL Unit GC200C08NK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200C08NK is a three-piece AirTAC G-series F.R.L. combination: separate air filter, pressure regulator and lubricator, mounted at size 200 on PT1/4 (1/4 in) ports. It keeps the standard 40 um element and the default differential-pressure drain and is supplied without a gauge; the regulator adjusts from 0.15-0.9 MPa (20-130 psi). The K in the code adds a reverse (check) valve, which holds the downstream circuit if the upstream supply is shut off. Maximum inlet pressure is 1.0 MPa (145 psi), and the filter and lubricator bowls are polycarbonate (PC) at this size.
It is a genuine AirTAC part for compressed air, rated -5 to 70 C (non-freezing). The G-series combination range steps from size 200 to 600, with 40 um or 5 um filtration, differential-pressure, automatic or manual drains, check-valve or plain builds, and PT as the standard thread with G (BSPP) and NPT available to order. Flow is published as curves rather than a single rating, so we confirm the datasheet figures on request before you order.
| Model | Airtac GC FRL Unit GC200C08NK |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeds the lift and lip cylinders of a warehouse dock leveler. The check valve keeps the downstream circuit held if the upstream supply is shut off, which matters where a positioned platform must not vent back.
Supplies the clamp cylinders on a press-fit or staking station; if the main air is isolated for changeover, the check valve holds the clamped circuit instead of letting it vent.
Conditions air to the feed-roller and hold-down actuators of a wire cut-and-strip machine, with 40 um filtration ahead of the valves, a fixed regulator setting and oil mist for the cylinders.
Size 200 with PT1/4 ports is the entry step; the 300, 400 and 600 sizes raise the port and the air demand they suit. The differential-pressure drain is the default, with automatic and manual draining as catalogue options. Keep the check valve where clamps, lifts or grippers must hold their state if the supply is isolated; choose the plain N build otherwise. The standard 40 um element suits general valves and cylinders, with the 5 um W build for finer protection. No gauge is fitted, but gauge builds are orderable, and the thread is PT as standard with G (BSPP) and NPT to order. Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
None is published as a single rating: AirTAC gives G-series flow as curves only. Share the duty you are sizing for and we will confirm the right size and flow behaviour from the datasheet on request.
K fits a reverse (check) valve in the unit. If the upstream supply is shut off or lost, the valve holds the downstream circuit instead of letting it vent back, which is useful for clamps, lifts and grippers that must keep their state. Choose the plain GC200C08N if you do not need that.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.