The AirTAC GC FRL Unit GC200C08NWK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$77.48 $83.09Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C08NWK

GC200C08NWK is a genuine AirTAC GC three-unit F.R.L. combination: a separate GF air filter, GR pressure regulator and GL lubricator assembled into one conditioned-air train. This 200-size set is threaded PT1/4 (1/4 in), carries a 5 um filter element, uses the differential-pressure drain on the filter bowl, is supplied without a pressure gauge, and has a reverse (check) valve fitted. The polycarbonate bowls on the filter and lubricator are rated for compressed air at up to 1.0 MPa (145 psi) inlet and -5 to 70 C, and the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi).

The GC series is offered in 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, 40 um standard or 5 um (W) elements, differential-pressure, automatic or manual drains, embedded square or round external gauges scaled in MPa, psi or bar, and PT, G or NPT threads. AirTAC publishes flow for these units as characteristic curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

Airtac GC FRL Unit GC200C08NWK Technical Specifications

ModelAirtac GC FRL Unit GC200C08NWK
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C08NWK

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C08NWK Is Used

precision_manufacturing

Benchtop pick-and-place head

Conditions the supply to the small cylinders and directional valves of a benchtop pick-and-place unit on an electronics assembly bench; the 5 um element suits the fine pilot orifices of the valves.

valve

Piloted process-valve skid

Feeds pilot air to solenoid-piloted process valves on a compact dosing or blending skid, with the regulator set to the pilot pressure the valve maker specifies and the check valve blocking backflow toward the supply.

build

Swing clamps on a small milling fixture

Supplies filtered, regulated and lubricated air to the swing clamps that hold workpieces on a small milling fixture, keeping the clamp cylinders consistently pressurized through the cycle.

Is the Airtac GC FRL Unit GC200C08NWK the Right Station?

Your real choices inside the GC family are the size and port (200 at PT1/4 here; larger sizes pass more flow), the drain (differential-pressure as coded here, automatic, or manual - a manual-drain set widens the regulator range to 0.05-0.9 MPa (7-130 psi)), the element grade (5 um as coded, or the 40 um standard), the gauge (none on this code; square embedded or round external with MPa, psi or bar scales) and the thread (PT standard, with G and NPT as catalogue options). The fitted reverse valve blocks downstream pressure from pushing back toward the regulator.

Flow is published as curves, not a single rating, so send us your pressure and consumption points and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C08NWK FAQ

AirTAC publishes GC flow as characteristic curves rather than a single rated figure, so there is no one l/min number to quote here. Send us your working pressure and required flow and we will confirm sizing from the datasheet on request.

N means no pressure gauge is fitted. Other GC codes carry an embedded square gauge or a round external gauge scaled in MPa (1), psi (2) or bar (3), so a gauge version can be selected if you want a local pressure reading at the set.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C08NWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C08NWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.