The AirTAC GC FRL Unit GC300C08ANW is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$103.82 $110.08Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C08ANW

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and a lubricator assembled as one set, covering filtration, regulation and lubrication in a single order line. This configuration is size 300 with 1/4 in. PT ports, a 5 um filter element (the W option), an automatic drain on the filter bowl and no gauge. The finer 5 um element gives a cleaner cut-off than the standard 40 um grade, and the automatic drain ejects condensate without operator attention. The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with this drain type.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in., PT, G or NPT threads, manual, automatic or differential-pressure drains, 40 um or 5 um elements and gauge options. Max working pressure is 1.0 MPa (145 psi); temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet data for your application.

Airtac GC FRL Unit GC300C08ANW Technical Specifications

ModelAirtac GC FRL Unit GC300C08ANW
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C08ANW

GC300G-series F.R.L. combination, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C0 filter, GR300-C0 regulator and GL300-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C08ANW Is Used

science

Laboratory pneumatic test benches

Conditioning unit feeding the air cylinders and jet nozzles on a lab or QC test bench, where the 5 um element keeps fine particulate away from precision pneumatic components.

settings_input_component

PLC-controlled pick-and-place cells

Point-of-use F.R.L. for the valve manifolds and gripper cylinders on an automated pick-and-place cell, with regulated pressure and oil mist for the actuators and a 5 um element upstream.

handyman

Furniture-shop spray and nailing station

Supply set for nail guns and air-assist spray equipment at a woodworking finishing station, giving filtered, regulated and lubricated air at each workstation drop.

Is the Airtac GC FRL Unit GC300C08ANW the Right Station?

Pick the size and port step (200 to 600, 1/8 to 1 in.) against the air demand of the equipment being fed; size 300 with a 1/4 in. PT port is a common choice for individual machines and tool circuits. This unit carries the 5 um (W) element - choose it over the standard 40 um grade where finer particulate protection is wanted, and pair it with the automatic drain where the bowl cannot be drained by hand. Gauge, thread (PT standard, G or NPT to order) and bracket options are selectable.

Because flow for the GC series is published as curves and not as a single rating, ask us to confirm sizing against your air consumption before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C0 regulator with a GF300-C0 filter on that branch.

Airtac GC FRL Unit GC300C08ANW FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so no single number is quoted here. Tell us your working pressure and the air consumption of the equipment to be fed and we will confirm the correct size from the datasheet on request.

The GC filter is offered with a 40 um standard element or a 5 um optional (W) element. This unit has the 5 um grade, which gives finer particulate removal - a common choice where precision valves, probes or sensors sit downstream. If general protection of cylinders and tools is all that is needed, the standard 40 um grade is the usual selection.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C08ANW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C08ANW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.