The AirTAC GC FRL Unit GC300C08C1WK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC300C08C1WK is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and lubricator, assembled for 1/4 in. PT pipework. The W option fits the fine 5 um filter element with a differential-pressure drain; the regulator holds your set downstream pressure over a 0.15-0.9 MPa (20-130 psi) range; the lubricator adds oil mist for downstream actuators. The C1 option adds an external round gauge scaled in MPa, and the K option fits a reverse (check) valve that keeps downstream pressure in place if the supply fails - useful for clamps and holding circuits. Compressed air is the only medium.
This is a genuine AirTAC part from the G series, which spans 200, 300, 400 and 600 sizes with ports from 1/8 in. to 1 in. and PT, G (BSPP) or NPT threads. On the 300 size the filter and lubricator bowls are PC (polycarbonate). Operating temperature is -5 to 70 C (non-freezing) and maximum working pressure is 1.0 MPa (145 psi). Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and the full datasheet for your application on request.
| Model | Airtac GC FRL Unit GC300C08C1WK |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C0 filter, GR300-C0 regulator and GL300-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C0 |
| Build order | Filter → regulator → lubricator |
Feeds swing clamps and edge clamps on a robotic welding fixture; the check valve keeps clamps engaged if plant air is lost mid-cycle, while the 5 um element protects the clamp internals.
Conditions the actuator air for diaphragm and ball valves on a process line, holding a stable set pressure to the positioners and retaining the actuator signal through brief supply dips.
Filters, regulates and lubricates the air to spray guns and air drives in a finishing booth, with the fine element helping keep the air clean enough for consistent finish work.
This GC300 code suits PT1/4 lines; GC200, GC400 and GC600 cover other ports and larger or smaller duties. Here you have the 5 um fine element (W), the round MPa gauge (C1) and the reverse valve (K); drop the W for the 40 um standard grade or the K if you do not need pressure retention. Drain is differential-pressure; automatic (A) and manual (M) variants exist, with the regulator span at 0.15-0.9 MPa (20-130 psi) for differential-pressure and automatic, 0.05-0.9 MPa (7-130 psi) for manual. A square (F) gauge with MPa, psi or bar scale is also available. Thread is PT as standard; G (BSPP) and NPT are orderable options. Flow is published only as curves, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C0 regulator with a GF300-C0 filter on that branch.
There is no single rated-flow figure to quote: AirTAC publishes GC300 performance as curves. Share your line pressure and the air demand of your equipment and we will confirm the right size and send the datasheet on request.
W fits the 5 um fine filter element instead of the standard 40 um, giving cleaner air to sensitive equipment. K fits a reverse (check) valve, so if upstream air fails the downstream circuit holds its pressure instead of venting back through the unit. Both sit inside the same three-piece F.R.L. on a PT1/4 connection.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.