AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C08F1

The AirTAC GC FRL Unit GC300C08F1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$99.03 $105.17Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C08F1

GC300C08F1 is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, pressure regulator and lubricator, assembled for 1/4 in. PT pipework. The filter removes water and particulate with the standard 40 um element and a differential-pressure drain; the regulator holds your set downstream pressure over a 0.15-0.9 MPa (20-130 psi) range; the lubricator meters oil mist to downstream cylinders and tools. The F1 option adds a square external gauge scaled in MPa for a clear panel-style pressure readout. Compressed air is the only medium.

This is a genuine AirTAC part from the G series, which spans 200, 300, 400 and 600 sizes with ports from 1/8 in. to 1 in. and PT, G (BSPP) or NPT threads. On the 300 size the filter and lubricator bowls are PC (polycarbonate). Operating temperature is -5 to 70 C (non-freezing) and maximum working pressure is 1.0 MPa (145 psi). Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and the full datasheet for your application on request.

Airtac GC FRL Unit GC300C08F1 Technical Specifications

ModelAirtac GC FRL Unit GC300C08F1
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C08F1

GC300G-series F.R.L. combination, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C0 filter, GR300-C0 regulator and GL300-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C08F1 Is Used

tune

Compressor room take-off point

Mounted at the take-off from a workshop compressor header, giving a dedicated branch of filtered, regulated, lubricated air with the square gauge readable at a glance from the wall.

settings_input_component

Pick-and-place station supply

Conditions the air feeding the vacuum generators and gripper cylinders on a PLC-controlled pick-and-place station, keeping actuator pressure stable from cycle to cycle.

conveyor_belt

Belt-conveyor pneumatics

Supplies the hold-down cylinders, diverters and belt-tensioners on a conveyor line, with the 40 um element keeping line debris out of the control valves.

Is the Airtac GC FRL Unit GC300C08F1 the Right Station?

This GC300 code is built for PT1/4 lines; step to GC200, GC400 or GC600 where ports or flow demand differ. The F1 here selects the square MPa gauge - round (C) is the alternative, and scales of psi (2) or bar (3) can be ordered. Element is the 40 um standard grade; choose W codes for the 5 um fine grade. Drain is differential-pressure on this code; automatic (A) and manual (M) variants exist, with the regulator span at 0.15-0.9 MPa (20-130 psi) for differential-pressure and automatic, 0.05-0.9 MPa (7-130 psi) for manual. K codes add a reverse valve. Thread is PT as standard; G (BSPP) and NPT are orderable options. Flow appears only as curves, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C0 regulator with a GF300-C0 filter on that branch.

Airtac GC FRL Unit GC300C08F1 FAQ

AirTAC does not publish a single rated-flow figure for the GC300 series - performance is given as curves. Send us your application pressures and air consumption and we will confirm the correct size and provide the datasheet on request.

The F1 code selects a square external gauge scaled in MPa, while C1 selects a round gauge with the same MPa scale. Both sit on the same three-piece F.R.L. with a PT1/4 port, 40 um element and differential-pressure drain; gauge style is purely the readout choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C08F1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C08F1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.