verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C08NK

The AirTAC GC FRL Unit GC300C08NK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$104.72 $111.01Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C08NK

The GC300C08NK is a genuine AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied as one coordinated set. This configuration is size 300 with 1/4 in PT ports, a 40 um standard filter element, differential-pressure drain on the filter bowl, no gauge fitted, and a reverse (check) valve fitted. In use it cleans water and particulate from the compressed air, holds the set downstream pressure and adds oil mist for downstream tools and cylinders.

This is a genuine AirTAC part within a range that spans size 200 to 600 with 1/8 in to 1 in ports, automatic, manual or differential-pressure drains, 40 um or 5 um filtration, gauge choices and G (BSPP) or NPT threads as catalogue options. Max working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C, non-freezing. Flow figures are published as curves rather than a single rated number, so we confirm datasheet figures on request.

Airtac GC FRL Unit GC300C08NK Technical Specifications

ModelAirtac GC FRL Unit GC300C08NK
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C08NK

GC300G-series F.R.L. combination, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C0 filter, GR300-C0 regulator and GL300-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C08NK Is Used

valve

Pneumatic stamping press supply

Point-of-use air prep for a small pneumatic stamping or marking press: one 1/4 in set filters the supply, regulates cylinder pressure and feeds oil mist to the valve stack and seals.

conveyor_belt

Bottling line gripper cylinders

Feeding the pick-and-place gripper cylinders on a bottling or canning conveyor with cleaned, regulated and lubricated air so fast-cycling directional valves hold up over long shifts.

science

Laboratory automation actuators

Supplying slide cylinders and rotary actuators in laboratory automation cells from a single 1/4 in conditioning point, with the reverse valve fitted in this configuration.

Is the Airtac GC FRL Unit GC300C08NK the Right Station?

Step through G-series sizes 200 to 600 as your flow demand and port size grow; size 300 with 1/4 in PT ports suits compact machine supply circuits. With the differential-pressure drain in this code, the regulator's adjustable range is 0.15-0.9 MPa (20-130 psi); choosing a manual-drain variant widens this to 0.05-0.9 MPa (7-130 psi). Filtration is the 40 um standard grade here, with 5 um (W) available for finer protection. This code carries no gauge (N); round or square gauges with MPa, psi or bar scales can be ordered instead. Thread is PT as standard, with G (BSPP) and NPT as orderable options, and a bracket is included by default. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C0 regulator with a GF300-C0 filter on that branch.

Airtac GC FRL Unit GC300C08NK FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote one number here. Send us your line pressure, downstream demand and acceptable pressure drop, and we will confirm the sizing from the datasheet on request before you order.

N means no pressure gauge is fitted on the regulator; K means a reverse (check) valve is fitted. If you want a gauge, order a variant with a round (C) or square (F) gauge in MPa, psi or bar scale. Filtration here is the 40 um standard grade; a W code specifies the 5 um element.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C08NK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C08NK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.