verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C10AC1

The AirTAC GC FRL Unit GC300C10AC1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$109.47 $115.87Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C10AC1

The GC300C10AC1 is a genuine AirTAC G-series three-unit F.R.L. combination: separate filter, regulator and lubricator ordered as one set. This configuration is size 300 with 3/8 in PT ports, the 40 um standard filter element, automatic drain on the filter bowl, and a round external pressure gauge on the MPa scale. It cleans, regulates and lubricates compressed air at a point of use, with the automatic drain ejecting collected condensate without manual attention.

This is a genuine AirTAC part within a G-series range running from size 200 to 600 with 1/8 in to 1 in ports, automatic, manual or differential-pressure drains, 40 um or 5 um grades, embedded square or external round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads as options. Max working pressure is 1.0 MPa (145 psi); temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm datasheet figures on request.

Airtac GC FRL Unit GC300C10AC1 Technical Specifications

ModelAirtac GC FRL Unit GC300C10AC1
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C10AC1

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C10AC1 Is Used

factory

Food packaging line air prep

A 3/8 in conditioning station for wrapper and filler cylinders on a food packaging line, where the automatic drain handles condensate on lines running without an operator at the unit.

conveyor_belt

Case erector and carton sealer feed

Supplying the vacuum cups and fold cylinders of a case erector or carton sealer, with filtered, regulated and lubricated air from one point of use.

engineering

Welding cell fixture clamps

Conditioning the air feeding fixture clamps and positioner actuators in a robotic welding cell, with the MPa round gauge giving the cell technician a visible set pressure.

Is the Airtac GC FRL Unit GC300C10AC1 the Right Station?

Size 300 with 3/8 in PT ports sits a step above the 1/4 in machines in the G-series, for lines where larger ports match the supply plumbing; sizes 200 to 600 are available as flow needs change. The A code here selects the automatic drain, which gives a regulator range of 0.15-0.9 MPa (20-130 psi); the manual-drain variant spans 0.05-0.9 MPa (7-130 psi). Filtration is the 40 um standard grade, with 5 um (W) for finer duty. The C1 code fits the external round gauge with MPa scale; square embedded gauges and psi or bar scales are alternatives. Thread is PT as standard with G (BSPP) and NPT orderable, and a bracket is included by default. Flow appears only as curves, so ask us to confirm sizing from the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

Airtac GC FRL Unit GC300C10AC1 FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so no one number is quoted here. Give us your line pressure, downstream demand and acceptable pressure drop, and we will confirm sizing from the datasheet on request.

A selects the automatic drain on the filter bowl instead of the default differential-pressure or manual types, and C1 fits the external round pressure gauge with MPa scale. With the automatic drain, the regulator adjusts over 0.15-0.9 MPa (20-130 psi). Thread is PT as standard, with G (BSPP) and NPT as catalogue options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C10AC1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C10AC1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.