verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C10AC1WK

The AirTAC GC FRL Unit GC300C10AC1WK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$120.82 $127.50Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C10AC1WK

The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator that together clean, regulate and lubricate compressed air. GC300C10AC1WK is a 300 size set with PT 3/8 in. ports, an automatic drain on the filter bowl, a 5 um fine filtration element, an external round pressure gauge on the MPa scale, and a reverse (check) valve fitted. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC family is offered in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in., drain options (differential-pressure, automatic or manual), 40 um or 5 um filtration, round or square gauges in MPa, psi or bar scales, G (BSPP) and NPT thread options, and an optional check valve. The filter and lubricator bowls in the 300 size are polycarbonate (PC). Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet for your application.

Airtac GC FRL Unit GC300C10AC1WK Technical Specifications

ModelAirtac GC FRL Unit GC300C10AC1WK
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C10AC1WK

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C10AC1WK Is Used

valve

Pneumatic valve island supply

Prepares air for a valve island running machine actuators; the 5 um element and fitted check valve keep fine dirt and reverse flow out of the downstream circuit.

engineering

Robot end-effector air circuit

Conditions supply air for the gripper and clamp circuits on a robot end-effector, with the check valve blocking backflow through the set at the end of each cycle.

factory

Bottling line filler actuators

Feeds filtered, regulated and lubricated air to the filler and capper actuators on a bottling line, with the automatic drain clearing condensate between washdown rounds.

Is the Airtac GC FRL Unit GC300C10AC1WK the Right Station?

Size the set to the line: 200, 300, 400 and 600 cover ports from 1/8 to 1 in., so match the 300 size and PT 3/8 in. port to the flow you need. Drain choice matters: differential-pressure is the default, automatic (as here) drains the bowl on its own, and manual-drain versions widen the regulator adjusting range to 0.05-0.9 MPa (7-130 psi); with this automatic-drain set the adjusting range is 0.15-0.9 MPa (20-130 psi). This code combines the W 5 um element (finer than the 40 um standard) with the K reverse/check valve, so air flows one way downstream and reverse flow is blocked. The gauge is a round external type on the MPa scale, with psi or bar scales available, and thread is PT as standard with G (BSPP) and NPT as catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

Airtac GC FRL Unit GC300C10AC1WK FAQ

AirTAC publishes flow for the GC series as curves, not a single rated figure, so we do not quote a number here. Send us your line details and we will confirm the flow curve and sizing from the datasheet on request.

A is the automatic drain on the filter bowl, C is the round external gauge and 1 is its MPa scale, W selects the 5 um element over the 40 um standard, and K fits the reverse/check valve. The set is the 300 size with PT 3/8 in. ports.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C10AC1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C10AC1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.