
The AirTAC GC FRL Unit GC300C10AF1W is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC300C10AF1W is a three-piece F.R.L. combination: separate filter, regulator and lubricator that clean compressed air, hold a set downstream pressure and deliver oil mist to valves, cylinders and tools. The W code specifies the fine 5 um filter element instead of the standard 40 um, an automatic drain empties the polycarbonate filter bowl, and the standard regulator carries an embedded square gauge on an MPa scale. Port size is 3/8 in with PT thread.
This is a genuine AirTAC part. The G-series combination comes in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, in PT (standard), G or NPT thread, with a choice of drain type, filter grade, gauge type and scale, and optional check valve. Maximum working pressure is 1.0 MPa (145 psi); temperature range is -5 to 70 C, non-freezing. Flow figures are published as curves, not a single rating, and we confirm datasheet details on request.
| Model | Airtac GC FRL Unit GC300C10AF1W |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Finer 5 um filtration ahead of spray equipment on a finishing line helps keep water and particulate out of the air feeding the spray gun and its regulator.
Provides filtered, regulated and lubricated air to a panel of directional valves and logic components on an automation line, with the MPa gauge showing set pressure at a glance.
Feeds impact drivers and nutrunners at an assembly workstation with clean, pressure-stabilised, oil-misted air, while the automatic drain removes condensate without daily attention.
Choose size (200/300/400/600) to match the port and air demand; this 300 set fits 3/8 in PT lines. With automatic drain the regulator range is 0.15-0.9 MPa (20-130 psi). The W code selects 5 um filtration where finer particle removal is wanted; the standard alternative is 40 um. The F1 code gives the embedded square gauge on an MPa scale (psi and bar scales are orderable). PT is the standard thread; G and NPT are catalogue options to order, and a mounting bracket is optional.
Flow for this series appears as curves rather than a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
Flow for this series is published as performance curves, not as a single rated number, so we do not quote one figure. Share your pressure and air demand and we will confirm the correct size from the datasheet on request.
W specifies the finer 5 um filter element, suited to applications that want finer particle removal ahead of sensitive valves or finishing equipment. Without W the set carries the standard 40 um element; every other part of the code decodes the same.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.