verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C10AF1WK

The AirTAC GC FRL Unit GC300C10AF1WK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$120.82 $127.50Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C10AF1WK

The GC300C10AF1WK is a three-piece F.R.L. combination: separate filter, regulator and lubricator that clean the air, hold a set downstream pressure and supply oil mist to downstream equipment. The W code gives the fine 5 um filter element, the automatic drain empties the polycarbonate filter bowl, the standard regulator has an embedded square MPa gauge, and the K code adds a reverse/check valve to the regulator section. Ports are 3/8 in with PT thread.

This is a genuine AirTAC part. The G-series combination is available in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, in PT (standard), G or NPT thread, with a choice of drain type, 40 um or 5 um filtration, gauge type and scale, and optional check valve. Maximum working pressure is 1.0 MPa (145 psi); temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating; we confirm datasheet figures on request.

Airtac GC FRL Unit GC300C10AF1WK Technical Specifications

ModelAirtac GC FRL Unit GC300C10AF1WK
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C10AF1WK

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C10AF1WK Is Used

valve

Pneumatic press hold-circuit supply

Prepares air for a small pneumatic press where the check valve helps maintain the downstream circuit if the main supply line loses pressure mid-stroke.

local_shipping

Trailer and body-building rigs

Conditions air for clamps, lifts and air tools at a vehicle body assembly bay, with 5 um filtration, automatic condensate draining and oil mist for the hand tools.

science

Laboratory automation skid

Supplies clean, regulated and lubricated air to grippers and mini-cylinders on a lab automation skid, with the MPa gauge letting technicians verify the set pressure.

Is the Airtac GC FRL Unit GC300C10AF1WK the Right Station?

Size the set (200/300/400/600) to the port and air demand; this 300 combination fits 3/8 in PT pipework. With automatic drain the regulator adjusts over 0.15-0.9 MPa (20-130 psi). W selects 5 um filtration (40 um is the standard alternative) and K fits the reverse/check valve. The F1 code gives the embedded square gauge on an MPa scale, with psi and bar scales orderable. PT is the standard thread; G and NPT are catalogue options to order, and a mounting bracket is optional.

Flow for this series is published as curves, not a single rated figure, so send us your application details and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

Airtac GC FRL Unit GC300C10AF1WK FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so there is no single number to quote here. Give us your working pressure and consumption and we will confirm the sizing from the datasheet on request.

Only the K: the WK version has a reverse/check valve fitted in the regulator section, while the plain W version has none. Both carry the 5 um element, automatic drain, standard regulator and square MPa gauge, in 3/8 in PT.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C10AF1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C10AF1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.