The AirTAC GC FRL Unit GC300C10ANK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series puts the three classic air-treatment functions in one ordered set: a separate filter to remove water and particulate, a separate regulator to set downstream pressure, and a separate lubricator to feed oil mist to downstream equipment. This configuration is the size 300 set with 3/8 in PT ports, automatic drain on the filter bowl, the standard 40 um filter element, no gauge fitted, and a reverse (check) valve fitted. Maximum working pressure is 1.0 MPa (145 psi), the regulator adjustment range is 0.15-0.9 MPa (20-130 psi), and operating temperature is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. GC sets come in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and G (BSPP) or NPT threads are available as catalogue options alongside the PT standard. On the size 300 filter and lubricator bowls the material is PC (polycarbonate). AirTAC publishes flow for this series as performance curves rather than a single rated figure, so we confirm sizing and full datasheet values on request.
| Model | Airtac GC FRL Unit GC300C10ANK |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Filters, regulates and lubricates the supply feeding a stamping press cylinder bank, with the check valve holding the downstream circuit's setting when upstream air is interrupted.
Prepares air for the cylinders and air bellows that push, divert and stop cartons on a packaging conveyor, with automatic drain keeping the filter bowl clear between shifts.
Serves as the treatment point ahead of filler and capper valve manifolds on a bottling line, where the 40 um element removes water and debris before the machine valves.
Size 300 with 3/8 in ports sits in the middle of the GC range (200/300/400/600); step up or down as your line's air demand requires. Drain types in the series are automatic, manual and the default differential-pressure - this version is automatic, which suits installations that are not checked daily. Filtration here is the standard 40 um element; a 5 um (W) element is offered where finer pre-filtration is needed. Gauge codes run from none (N, as here) to an embedded square gauge or an external round gauge on MPa, psi or bar scales. Thread is PT as standard, with G (BSPP) and NPT orderable as catalogue options. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
AirTAC publishes G-series flow as performance curves, not as a single rated figure, so we do not quote one number here. Send us your line flow and working pressure and we will confirm sizing against the datasheet on request.
A decodes to an automatic drain on the filter bowl, so condensate is ejected without manual attention. K means a reverse (check) valve is fitted. Manual-drain and differential-pressure-drain versions of the same set are also available in the series.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.