verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C10C1

The AirTAC GC FRL Unit GC300C10C1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$99.03 $105.17Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C10C1

The AirTAC GC series delivers the three air-treatment functions as separate units in one set: filter, regulator and lubricator. This configuration is the size 300 set with 3/8 in PT ports, the default differential-pressure drain on the filter bowl, the standard 40 um filter element, and the C1 gauge option - an external round gauge reading in MPa. No reverse valve is fitted. Maximum working pressure is 1.0 MPa (145 psi), the regulator adjustment range is 0.15-0.9 MPa (20-130 psi), and operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC series runs in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and G (BSPP) or NPT threads are available as catalogue options beside the PT standard. The size 300 filter and lubricator bowls are PC (polycarbonate). Because flow is published as curves rather than a single rating, we confirm sizing and datasheet figures on request.

Airtac GC FRL Unit GC300C10C1 Technical Specifications

ModelAirtac GC FRL Unit GC300C10C1
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C10C1

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C10C1 Is Used

settings_input_component

CNC machining center air supply

Filters, regulates and lubricates the supply to a machining center's pneumatic tool-change and clamping circuits, with the MPa round gauge giving operators a visible line-pressure reference at the machine.

local_shipping

Vehicle assembly line air tools

Conditions the branch feeding pneumatic impact wrenches and nutrunners on a vehicle assembly line, where lubrication keeps the tools fed and the gauge shows the set pressure.

view_module

Sortation module actuation

Prepares air for the pop-up wheels and diverters of a parcel sortation module, with the standard 40 um element and differential-pressure drain suiting a maintained plant-air system.

Is the Airtac GC FRL Unit GC300C10C1 the Right Station?

This is the blank-drain, blank-grade configuration: differential-pressure drain and the standard 40 um element, so nothing needs emptying on a fixed schedule the way a manual drain does. If you want condensate ejected without operator action, step to the automatic-drain (A) versions of the same set. The C1 gauge gives an external round gauge on an MPa scale; psi (2) and bar (3) scales and the embedded square gauge are the other gauge choices. Size 300 with 3/8 in PT ports is the middle step of the range (200/300/400/600), with G (BSPP) and NPT as orderable thread options. AirTAC publishes flow only as curves, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

Airtac GC FRL Unit GC300C10C1 FAQ

AirTAC does not publish a single rated flow figure for G-series units - flow appears as performance curves. Tell us the flow and pressure your line needs and we will confirm sizing against the datasheet on request.

C1 decodes to an external round gauge with an MPa scale; other gauge codes offer psi or bar scales or the embedded square gauge. With no drain letter, the filter uses the default differential-pressure drain; automatic (A) and manual (M) drain versions of this set are also available.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C10C1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C10C1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.