The AirTAC GC FRL Unit GC300C10F1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC300C10F1 is an AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set. This 300-size configuration is ported PT3/8, uses the differential-pressure drain, carries the standard 40 um filtration grade, and is fitted with the embedded square MPa pressure gauge. The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with this drain type, and the set handles compressed air at up to 1.0 MPa (145 psi) inlet in a -5 to 70 C (non-freezing) environment.
This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes from 1/8 in to 1 in ports, and this 300 size uses PC (polycarbonate) bowls on the filter and lubricator sections. Flow for the series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet and sizing figures for your application on request.
| Model | Airtac GC FRL Unit GC300C10F1 |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Conditions the air feeding the push and clamp cylinders of a palletizing machine, with the square MPa gauge showing regulated pressure directly on the set.
Feeds the tensioning and stopper cylinders along a food-grade conveyor line, delivering filtered, regulated and lubricated air at each conditioned drop.
Serves as the conditioned supply point for impact wrenches and other air tools at a plant maintenance bench, combining filtration, regulation and lubrication in one unit.
The F1 in this code selects the embedded square gauge with an MPa scale; the C variant with a round gauge is the alternative on the same 300-size, PT3/8 body. The 40 um element is the standard grade, with the 5 um W variant orderable. The differential-pressure drain runs unattended, while automatic (A) and manual (M) drains are catalogue variants. Step to 400 or 200 size if your port or flow requirement differs from 3/8 in. PT is the standard thread, with G (BSPP) and NPT orderable as options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
Flow for the G series is published as curves, not as a single rated figure, so we do not quote a number here. Ask us and we will confirm the datasheet and the curve for this 300-size, 3/8 in configuration against your application on request.
The F1 in the code selects the embedded square gauge with an MPa scale. If you prefer the round gauge style, the C variant of the same 300-size, PT3/8 combination is available as a catalogue option.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.