verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C10MC1W

The AirTAC GC FRL Unit GC300C10MC1W is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$99.03 $105.17Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C10MC1W

This GC300C10MC1W is AirTAC's three-piece F.R.L. combination - separate filter, regulator and lubricator - in size 300 with PT3/8 ports. The W in the code specifies the fine 5 um filter element instead of the 40 um standard, the filter bowl has a manual drain, and an external round pressure gauge with MPa scale is fitted.

It is a genuine AirTAC part for compressed air only, from a series offered in sizes 200, 300, 400 and 600 with automatic, manual or differential-pressure draining and PT, G or NPT threads. The size 300 bowls are polycarbonate, the working temperature range is -5 to 70 C (non-freezing), and the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) on this manual-drain version. Flow is published as curves rather than a single figure, so we confirm datasheet numbers on request.

Airtac GC FRL Unit GC300C10MC1W Technical Specifications

ModelAirtac GC FRL Unit GC300C10MC1W
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C10MC1W

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C10MC1W Is Used

science

Laboratory automation air supply

Feeds grippers and sampling actuators in a lab automation cell, where the 5 um element protects fine pilot valves from particulate carryover.

precision_manufacturing

CNC machine tool air preparation

Prepares the air for a CNC machining centre's tool-change cylinder and air blast, with the gauge showing the regulated pressure at the machine.

view_module

Pick-and-place module on a packaging machine

Supplies the vacuum generators and cylinders of a pick-and-place module, with lubricator mist conditioning the actuator air.

Is the Airtac GC FRL Unit GC300C10MC1W the Right Station?

Stay at size 300 with PT3/8 if your pipework and air demand match; the 200 and 400/600 steps cover smaller and larger flows. This W version's 5 um element suits circuits with sensitive valves or cylinders that the standard 40 um grade would leave exposed; keep 40 um where coarse protection is enough. Manual drain means periodic attention to the bowl - specify automatic (A) for unattended installations. The round gauge reads in MPa and can be ordered with psi (2) or bar (3) scale instead. PT is the standard thread; G and NPT are catalogue options. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

Airtac GC FRL Unit GC300C10MC1W FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a number here. Tell us your flow and pressure requirements and we will confirm the sizing from the datasheet before you order.

The W code specifies the 5 um element, which captures finer particles than the 40 um standard - a good fit for precision valves and cylinders. If coarse protection is sufficient, the same set without W carries the 40 um grade; both are orderable in size 300.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C10MC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C10MC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.