The AirTAC GC FRL Unit GC300C10MC1WK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC300C10MC1WK is AirTAC's three-unit F.R.L. combination - a separate filter, regulator and lubricator - in size 300 with PT3/8 ports. It carries the fine 5 um filter element (W), a manual drain on the filter bowl, an external round pressure gauge with MPa scale, and a reverse (check) valve fitted to prevent backflow through the set.
This is a genuine AirTAC part for compressed air only. The G series is offered in sizes 200, 300, 400 and 600 with your choice of drain type, 40 um or 5 um filtration, and PT, G or NPT threads. The size 300 bowls are polycarbonate, the temperature range is -5 to 70 C (non-freezing), and the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) on this manual-drain version. Flow is published as curves rather than a single rating, so we confirm datasheet figures on request.
| Model | Airtac GC FRL Unit GC300C10MC1WK |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Feeds the rotary indexing table's drive cylinder, with the check valve holding the downstream circuit stable if the header pressure drops.
A serviced drop at a maintenance bay for grinders and ratchets, combining fine filtration, set pressure and oil-mist lubrication in one point.
Conditions the air to a loom's clutch and brake cylinders, where the 5 um element protects the quick-exhaust and control valves.
Size 300 with PT3/8 ports is the mid-range step in the G series; move to 200 or 400/600 as your flow and pipe size dictate. The 5 um element (W) gives finer filtration than the 40 um standard, and the check valve (K) is the decodable extra here - useful where a drop in supply must not pull air back from the downstream circuit. Manual drain suits attended installations; order the automatic (A) version for unattended ones. The MPa gauge scale can be switched to psi (2) or bar (3) at order time, and G or NPT threads are catalogue options beside the PT standard. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not state a number. Share your required flow and working pressure and we will confirm the sizing from the datasheet before you order.
K means a reverse (check) valve is fitted, so air cannot flow backwards through the set if the upstream supply fails. The same size 300 F.R.L. is available without it by dropping the K from the code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.