AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C10MN

The AirTAC GC FRL Unit GC300C10MN is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$93.38 $99.38Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C10MN

The AirTAC GC series is a three-unit F.R.L. combination: separate air filter, pressure regulator and lubricator assembled as one set, so filtration, regulation and oil-mist lubrication are handled in the correct order on one air line. This GC300C10MN is the 300 size with PT3/8 (PT thread) ports, a manual drain on the filter bowl, the standard 40 um filter element and no gauge fitted (N code). Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusts 0.05-0.9 MPa (7-130 psi) with the manual drain, the working temperature range is -5 to 70 C (non-freezing), and the 300-size filter bowl is PC (polycarbonate).

This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, PT as the standard thread and G (BSPP) or NPT as catalogue options, plus automatic, manual or differential-pressure drains, 40 um or 5 um elements and gauge variants. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing figures for your application on request.

Airtac GC FRL Unit GC300C10MN Technical Specifications

ModelAirtac GC FRL Unit GC300C10MN
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C10MN

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C10MN Is Used

precision_manufacturing

Sheet metal press brake tooling

Conditions the air to sheet-support arms and part ejector cylinders on a press brake, where the standard 40 um grade and no-gauge configuration suit a panel with its own master gauges.

view_module

Injection molding take-out robots

Feeds vacuum cups and grip cylinders on molding-machine take-out robots, combining filter, regulator and lubricator at the 3/8 inch drop with the manual drain for scheduled draining.

air

Woodworking shop pneumatic tools

Supplies nailers, staplers and air sanders at a cabinet shop manifold, giving one filtered, regulated, oiled supply point for several 3/8 inch tool stations.

Is the Airtac GC FRL Unit GC300C10MN the Right Station?

Match the set to your line by choosing GC200, GC300, GC400 or GC600; this model is the 300 size with 3/8 inch PT ports. The drain is manual, which gives the wider 0.05-0.9 MPa regulator range; automatic and differential-pressure drains offer a 0.15-0.9 MPa (20-130 psi) range. Filtration is the standard 40 um grade; specify the W code for the 5 um element if finer filtration is needed. The N code means no gauge - pick a gauge variant (square or round, MPa, psi or bar scale) if you want a local pressure reading. Thread is PT as standard, G and NPT are order options, and a bracket is optional. Flow appears as curves, not a single rating, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

Airtac GC FRL Unit GC300C10MN FAQ

AirTAC does not publish a single rated flow figure for the GC series - flow is given as characteristic curves. Tell us your operating pressures and air consumption and we will confirm the relevant curve and full datasheet figures for this model on request.

N means no pressure gauge is fitted on the regulator, so the set is supplied without a local pressure read-out. If you want one, the GC300 family is available with an embedded square gauge or an external round gauge in MPa, psi or bar scales - just select the corresponding gauge code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C10MN

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C10MN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.