verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C10MNW

The AirTAC GC FRL Unit GC300C10MNW is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$93.38 $99.38Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C10MNW

GC300C10MNW is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator handling filtration, pressure regulation and oil-mist lubrication on one compressed-air line. This 300-size set is ported PT3/8 (3/8 in). The filter bowl drains manually and carries the finer 5 um element (W grade), and the standard-type regulator adjusts from 0.05 to 0.9 MPa (7-130 psi). No gauge and no reverse valve are included in this configuration. Maximum working pressure is 1.0 MPa (145 psi) and the operating range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The G series runs in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, PT, G (BSPP) and NPT thread options, differential-pressure, automatic or manual drains, 40 um or 5 um filtration, gauge choices and optional brackets. In this 300 size the filter and lubricator bowls are polycarbonate. AirTAC publishes G-series flow as curves rather than a single rated figure, so ask us to confirm the datasheet numbers for your application.

Airtac GC FRL Unit GC300C10MNW Technical Specifications

ModelAirtac GC FRL Unit GC300C10MNW
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C10MNW

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C10MNW Is Used

factory

Furniture finishing spray lines

Air preparation for spray guns and finishing stations in a woodshop finishing line, where the 5 um element supports cleaner air ahead of the atomising circuit and the lubricator feeds tool air.

settings_input_component

Pneumatic control panels

Supplying clean, regulated, lubricated air to the directional valves and pilot circuits inside a machine control panel, all from one 3/8 in PT supply point.

conveyor_belt

Bottling line actuators

Conditioning the air that drives filler-head and capping-head cylinders on a bottling conveyor, with a manual drain for scheduled bowl emptying between shifts.

Is the Airtac GC FRL Unit GC300C10MNW the Right Station?

Size the set (200/300/400/600) and pick the port step against actual air demand; this 300 set is ported 3/8 in PT. The W code here selects the 5 um element instead of the 40 um standard - the right call when finer air matters downstream, with manual drain (as coded) suiting supervised installations and automatic or differential-pressure drains suiting unattended lines. This set is supplied without a gauge; embedded square gauges and external round gauges with MPa, psi or bar scales are catalogue options. PT is the standard thread, with G (BSPP) and NPT orderable, and a bracket is optional. Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

Airtac GC FRL Unit GC300C10MNW FAQ

AirTAC publishes G-series capacity as flow curves rather than a single rated figure, so no single number is stated here. Share your inlet pressure and demand and we will confirm the flow from the datasheet on request before you order.

The W in this code selects the 5 um filter grade, a finer cut than the 40 um standard element, for duty where cleaner air matters downstream of the filter stage. For general machine air, the same set without the W code carries the 40 um grade.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C10MNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C10MNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.