The AirTAC GC FRL Unit GC300C10NW is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC300C10NW is a genuine AirTAC G-series three-unit F.R.L. combination: separate air filter, pressure regulator and oil-mist lubricator conditioning compressed air as one set. This configuration is size 300 with PT3/8 in ports, differential-pressure drain, 5 um fine filtration (the W option), no gauge and no reverse valve. In use the 5 um element strips finer particulate than the standard 40 um grade, the regulator holds a set downstream pressure (0.15-0.9 MPa / 20-130 psi on this drain type), and the lubricator meters oil mist downstream. Maximum working pressure is 1.0 MPa (145 psi), media is compressed air only, operating range -5 to 70 C (non-freezing). At size 300 the filter and lubricator bowls are PC (polycarbonate); the regulator has no bowl.
The G series is available in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, plus drain, filtration grade, gauge and thread options. Published figures cover function, ports, pressures and temperature; flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.
| Model | Airtac GC FRL Unit GC300C10NW |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Conditioning shop air feeding pneumatic samplers and valve actuators around lab-scale analysers, where 5 um filtration keeps finer debris out of pilot lines.
Supplying clamping fixtures and part-ejection cylinders on PCB assembly benches, with oil mist protecting the small cylinders cycle after cycle.
Conditioning supply air to pneumatic ball-valve actuators on a process skid; the 5 um element protects pilot solenoids and the lubricator serves the actuator seals.
Pick the size (200 to 600) to match your port and demand; this 300 unit is PT3/8 in. Choose filtration: 40 um standard or the 5 um W grade fitted here for finer protection. Drain is differential-pressure (default), or specify A automatic or M manual. Gauges can be omitted (N, as here) or ordered round or square with MPa, psi or bar scale. PT is the standard thread, with G (BSPP) and NPT as catalogue options. Flow is published as curves rather than a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
There is no single rated flow figure to quote: AirTAC publishes GC-series flow as curves. Send us your working pressure and demand and we will confirm the flow and datasheet figures for this PT3/8 in, 5 um unit on request.
40 um is the standard grade for general water and particulate removal; the W option (fitted in this GC300C10NW) gives 5 um for finer protection of pilot valves and close-tolerance components. Choose 5 um when downstream devices are sensitive to small debris.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.