The AirTAC GC FRL Unit GC300C15AC1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC300C15AC1 is a genuine AirTAC G-series three-unit F.R.L. combination: separate air filter, pressure regulator and oil-mist lubricator conditioning compressed air as one set. This configuration is size 300 with PT1/2 in ports, automatic drain, standard 40 um filtration, an external round gauge on MPa scale, standard regulator type and no reverse valve. In use the filter removes water and particulate, condensate is discharged from the bowl automatically rather than on a manual round, the regulator holds a set downstream pressure (0.15-0.9 MPa / 20-130 psi on this drain type) readable on the MPa gauge, and the lubricator meters oil mist downstream. Maximum working pressure is 1.0 MPa (145 psi), media is compressed air only, operating range -5 to 70 C (non-freezing). At size 300 the filter and lubricator bowls are PC (polycarbonate); the regulator has no bowl.
The G series spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, with drain, filtration grade, gauge and thread options selectable across the family. Published figures cover function, ports, pressures and temperature; flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.
| Model | Airtac GC FRL Unit GC300C15AC1 |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Conditioning the 1/2 in supply feeding grippers, weld-gun clamps and purge-air lines on a spot-welding robot; the round MPa gauge lets the setter verify pressure at the cell.
Supplying filler-head lift cylinders, capper heads and reject pushers on a bottling line; the automatic drain clears bowl condensate without stopping for operator rounds.
Feeding a bank of directional valves and actuators on a machine control panel; the gauge shows the regulated setting and the auto drain keeps the filter bowl clear on a continuous line.
Match the size step (200 to 600) to your port and demand; this 300 unit gives PT1/2 in. Drain choice matters on duty cycles: automatic (A, as here) clears condensate without operator rounds, while differential-pressure (default) and manual (M) suit other regimes. Filtration is 40 um standard or 5 um with W. Gauge options are none (N), or round or square with MPa, psi or bar scale - this unit carries a round MPa gauge. PT is the standard thread; G (BSPP) and NPT are catalogue options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number. Send us your working pressure and required demand and we will confirm the flow and datasheet figures for this PT1/2 in unit on request.
A is the automatic drain, which discharges bowl condensate on its own instead of the differential-pressure default or a manual drain; C is the external round gauge and 1 is its MPa scale. The base code decodes as size 300, PT1/2 in ports, 40 um standard filtration, PT thread.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.