The AirTAC GC FRL Unit GC300C15ANK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC300C15ANK is an AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator working together to clean, regulate and oil-mist lubricate compressed air. This 300-size set has a 1/2 in PT port, an automatic drain on the filter bowl, the standard 40 um filter element, no gauge fitted, and a reverse (check) valve on the regulator. The automatic drain removes collected condensate without anyone opening the bowl, which suits installations that are not checked daily.
This is a genuine AirTAC part rated to 1.0 MPa (145 psi) maximum working pressure, -5 to 70 C (non-freezing), with PC (polycarbonate) bowls at this size and a regulator range of 0.15-0.9 MPa (20-130 psi) with automatic drain. The G series is also available in 200, 400 and 600 sizes, other ports, G (BSPP) or NPT threads, manual or differential-pressure drains, a 5 um element, gauge options and without the check valve. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your line on request.
| Model | Airtac GC FRL Unit GC300C15ANK |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Mounted at the drop of a packaging conveyor's air main, it removes condensate and debris, holds a steady regulated pressure to the line's pneumatic cylinders, and meters oil mist to the actuators that case, seal and divert product.
Feeding a bench of air impact drivers and nutrunners in an automotive assembly cell, it delivers filtered, pressure-controlled and lubricated air so the tools keep consistent torque output shift after shift.
Built into the pneumatics panel of a custom automation machine, the three-unit set conditions the whole machine supply at one point, and the check valve protects set pressure if the shop air header fluctuates.
Size 300 with a 1/2 in PT port sits mid-range in the G series; step up to 400/600 or down to 200 depending on the flow your machine needs. Drain choice matters: automatic (as here) empties the filter bowl on its own, manual is emptied by hand, and differential-pressure drains only when the element loads up. The standard 40 um element suits general plant air; order the W variant for 5 um when downstream valves and cylinders are more sensitive. No gauge is fitted on this code; gauge options can be added. PT is the standard thread, with G (BSPP) and NPT as catalogue options to specify, and the fitted check valve holds downstream pressure if the supply drops.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
AirTAC publishes flow for the G series as curves, not as a single rated number, so we do not quote a fixed figure here. Tell us your inlet pressure and the flow or cylinder demand of your application and we will confirm the sizing against the datasheet curves before you order.
The final K in the code means a reverse (check) valve is fitted, which blocks backflow and holds downstream pressure; the N means no gauge is included. If you want local pressure indication, ask about gauge options for this size when ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.