verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C15F1

The AirTAC GC FRL Unit GC300C15F1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$99.03 $105.17Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C15F1

The AirTAC GC series delivers a three-unit F.R.L. combination - separate filter, regulator and lubricator assembled as one set - so the air feeding your valves, cylinders and tools is cleaned, regulated and oil-mist lubricated. This GC300C15F1 is the 300 size with PT 1/2 ports. The filter carries the standard 40 um element with a differential-pressure drain, the regulator adjusts 0.15-0.9 MPa (20-130 psi), and the F code selects the embedded square gauge on the MPa scale. Maximum working pressure is 1.0 MPa (145 psi); temperature range is -5 to 70 C, non-freezing, and the 300-size filter and lubricator bowls are polycarbonate.

This is a genuine AirTAC part. The G-series comes in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, PT, G (BSPP) or NPT threads, and options covering drain type, filter grade, gauge and reverse valve. Flow for the series is published only as curves, not a single rated figure, so ask us to confirm flow and datasheet details against your application on request.

Airtac GC FRL Unit GC300C15F1 Technical Specifications

ModelAirtac GC FRL Unit GC300C15F1
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C15F1

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C15F1 Is Used

handyman

Assembly-bench air tools

Feeds filtered, regulated and lubricated air to nutrunners and impact tools at a manual assembly bench, with the square gauge easy to read at a glance.

conveyor_belt

Food-packaging conveyor actuation

Supplies conditioned air to the diverters and clamp cylinders along a packaging conveyor, keeping the actuation circuit served by one three-piece set.

engineering

Fixture clamping on a weld cell

Regulates and lubricates the air to fixture clamps around a weld cell, holding the clamping pressure the fixture was commissioned with.

Is the Airtac GC FRL Unit GC300C15F1 the Right Station?

The 300 size with PT 1/2 ports is the mid step of the range; move to 200, 400 or 600 to match your manifold port and demand. This code takes the standard 40 um element and differential-pressure drain, with automatic or manual drain and the 5 um element as orderable variants. The embedded square gauge reads in MPa; the round gauge is the alternative, and G (BSPP) or NPT threads can be specified instead of the PT standard, with an optional bracket. Flow appears only as curves, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

Airtac GC FRL Unit GC300C15F1 FAQ

We confirm flow from the datasheet on request, because AirTAC publishes this series as flow curves rather than a single rated figure. Share your working pressure and air demand and we will check the 300-size curve against your application before you order.

The F is the gauge code for the embedded square gauge and the 1 is its MPa scale; a round gauge with the same scale is the alternative C code. The rest of this code decodes as a 300-size three-unit F.R.L. set, PT 1/2 thread, standard 40 um element, differential-pressure drain and no reverse valve.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C15F1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C15F1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.