The AirTAC GC FRL Unit GC300C15F1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series delivers a three-unit F.R.L. combination - separate filter, regulator and lubricator assembled as one set - so the air feeding your valves, cylinders and tools is cleaned, regulated and oil-mist lubricated. This GC300C15F1 is the 300 size with PT 1/2 ports. The filter carries the standard 40 um element with a differential-pressure drain, the regulator adjusts 0.15-0.9 MPa (20-130 psi), and the F code selects the embedded square gauge on the MPa scale. Maximum working pressure is 1.0 MPa (145 psi); temperature range is -5 to 70 C, non-freezing, and the 300-size filter and lubricator bowls are polycarbonate.
This is a genuine AirTAC part. The G-series comes in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, PT, G (BSPP) or NPT threads, and options covering drain type, filter grade, gauge and reverse valve. Flow for the series is published only as curves, not a single rated figure, so ask us to confirm flow and datasheet details against your application on request.
| Model | Airtac GC FRL Unit GC300C15F1 |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to nutrunners and impact tools at a manual assembly bench, with the square gauge easy to read at a glance.
Supplies conditioned air to the diverters and clamp cylinders along a packaging conveyor, keeping the actuation circuit served by one three-piece set.
Regulates and lubricates the air to fixture clamps around a weld cell, holding the clamping pressure the fixture was commissioned with.
The 300 size with PT 1/2 ports is the mid step of the range; move to 200, 400 or 600 to match your manifold port and demand. This code takes the standard 40 um element and differential-pressure drain, with automatic or manual drain and the 5 um element as orderable variants. The embedded square gauge reads in MPa; the round gauge is the alternative, and G (BSPP) or NPT threads can be specified instead of the PT standard, with an optional bracket. Flow appears only as curves, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
We confirm flow from the datasheet on request, because AirTAC publishes this series as flow curves rather than a single rated figure. Share your working pressure and air demand and we will check the 300-size curve against your application before you order.
The F is the gauge code for the embedded square gauge and the 1 is its MPa scale; a round gauge with the same scale is the alternative C code. The rest of this code decodes as a 300-size three-unit F.R.L. set, PT 1/2 thread, standard 40 um element, differential-pressure drain and no reverse valve.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.