The AirTAC GC FRL Unit GC300C15F1K is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC300C15F1K is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, a pressure regulator and an air lubricator, plumbed for 1/2 in. PT ports. The filter stage carries the standard 40 um element with the default differential-pressure drain, the regulator is the standard type with the embedded square gauge reading in MPa (F1), and the K suffix means a reverse (check) valve is fitted. It runs on compressed air at up to 1.0 MPa (145 psi) and -5 to 70 C, with polycarbonate bowls on the filter and lubricator at this size.
This is a genuine AirTAC part from the GC range, which covers 200, 300, 400 and 600 sizes from 1/8 to 1 in. ports, with a choice of drain type, filter grade, gauge scale and thread. AirTAC publishes flow only as curves rather than a single rated figure, so we confirm the datasheet and flow data for your exact model on request.
| Model | Airtac GC FRL Unit GC300C15F1K |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Air preparation for pneumatic nutrunners and clamp cylinders on a car trim line, with the regulator set at the station and the K reverse-valve option specified for the cell.
Supplying treated air to stopper, gate and pusher cylinders along a bottling-hall conveyor, with a 40 um element against general plant air.
Conditioning dusty wood-shop air before it reaches the hold-down clamps and tool-change cylinders of a CNC router cell.
Size 300 with PT1/2 ports is the mid-large step of the G series; match the port to your pipe size and step between 200, 300, 400 and 600 as your air demand grows. The 40 um element suits general plant air - order the W variant where 5 um filtration is needed. This code leaves the drain position blank, so it uses the differential-pressure drain; automatic (A) and manual (M) drains are catalogue alternatives. The F1 square gauge reads MPa, and psi or bar scales plus an external round gauge can be ordered instead.
PT is the standard thread; G (BSPP) and NPT versions are ordered as catalogue options. Because rated flow is published only as curves and not as a single number, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote one number here. Send us your line pressure and air demand and we will confirm the datasheet curve and sizing for this exact model on request.
K means a reverse (check) valve is fitted in this combination. The same GC300C15 family is also available without it, and with drain, filter-grade, gauge-scale and thread options - tell us your circuit and we will confirm the right code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.