The AirTAC GC FRL Unit GC300C15MC1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator delivered as one set. This GC300C15MC1 is built in size 300 with 1/2 in PT ports, a manual drain on the filter bowl, the standard 40 um filter element and an external round pressure gauge with MPa scale. It strips water and particulate from compressed air, holds a set downstream pressure and meters oil mist into the line feeding your equipment.
This is a genuine AirTAC part. The GC series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, with differential-pressure, automatic or manual drains, a 40 um standard or 5 um (W) element, embedded square or external round gauges in MPa, psi or bar scales, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating; ask us and we will confirm the datasheet figures for your application.
| Model | Airtac GC FRL Unit GC300C15MC1 |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Feed the pneumatic panel of a CNC machining center: the filter removes water and pipe-scale from shop air, the regulator holds the set pressure to the clamping and tool-change circuits, and the lubricator mists oil to the machine's air cylinders and valves.
Supply the filling, capping and labeling stations of a beverage bottling line. One GC set upstream of the manifold gives clean, regulated, lubricated air to the grippers, diverters and stopper cylinders along the conveyor.
Run butterfly and ball valve actuators on a water treatment skid. The regulator holds the actuator supply steady while the filter and lubricator condition the air feeding the positioner and solenoid valves.
Size 300 with 1/2 in PT ports sits mid-range in the GC series; step up to 400 or 600, or down to 200, with the matching port if your line demands it. This version has a manual drain, which also widens the regulator adjustment range to 0.05-0.9 MPa (7-130 psi); automatic and differential-pressure drain versions adjust between 0.15-0.9 MPa (20-130 psi). The 40 um element is standard, with the W suffix giving 5 um where finer filtration matters. The C1 suffix specifies an external round gauge on MPa scale; psi or bar scales are alternatives. PT is the standard thread, with G (BSPP) and NPT as order options. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
AirTAC publishes GC series flow data as performance curves, not as a single rated figure, so we do not quote a number here. Tell us your working pressure and air demand and we will pull the datasheet curve for this size 300, 1/2 in unit and confirm it against your application before you order.
This model uses a manual drain: open the bowl drain periodically to purge collected water, which suits attended lines. It also gives the regulator a wider 0.05-0.9 MPa (7-130 psi) adjustment range; automatic (A) and differential-pressure drain versions adjust between 0.15-0.9 MPa (20-130 psi). Choose the A suffix for unattended duty.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.