verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C15MF1

The AirTAC GC FRL Unit GC300C15MF1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$99.03 $105.17Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C15MF1

GC300C15MF1 is a three-piece F.R.L. combination from AirTAC's G-series: a filter, a pressure regulator and a lubricator assembled as one size 300 unit for a 1/2 in PT supply line. In use it removes water and particulate from compressed air, holds a set downstream pressure and feeds a controlled oil mist to downstream actuators and tools. This code carries a manual drain on the filter bowl, the standard 40 um filter element and an embedded square pressure gauge scaled in MPa; with the manual-drain bowl, the regulator adjusts over 0.05-0.9 MPa (7-130 psi).

This is a genuine AirTAC part. The G-series runs from size 200 to 600 with ports from 1/8 to 1 in, and options include G (BSPP) or NPT threads, automatic or manual drains, a 5 um element (code W), an external round gauge in psi or bar scale, and a reverse/check valve (code K). Maximum working pressure is 1.0 MPa (145 psi), the temperature range is -5 to 70 C (non-freezing), and size 300 bowls are polycarbonate. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures on request.

Airtac GC FRL Unit GC300C15MF1 Technical Specifications

ModelAirtac GC FRL Unit GC300C15MF1
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C15MF1

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C15MF1 Is Used

precision_manufacturing

CNC machining-center pneumatics

Feeds air-operated workholding clamps and chip-ejection jets on a machining center from the shop 1/2 in main, so clamps hold a consistent set pressure through every cycle.

view_module

Carton-forming packaging line

Supplies case erectors and flap-closing cylinders on a packaging line, where the lubricator keeps cylinder seals running on a controlled oil mist and the regulator stabilises pressure across the line.

settings_input_component

Pick-and-place robot grippers

Serves the valve manifold feeding pneumatic grippers on a pick-and-place robot cell, combining filtered, regulated and lubricated air in one size 300 unit at the drop.

Is the Airtac GC FRL Unit GC300C15MF1 the Right Station?

Size 300 with a 1/2 in PT port is the mid step of the G-series; move up to 400/600 or down to 200 if the line needs a different port and flow capacity. The 40 um element is the standard grade for general plant air - choose code W (5 um) only where finer pre-filtration is genuinely needed ahead of sensitive components. Gauge scale is fixed here at MPa, but psi or bar round external gauges can be ordered, and the thread can be specified as G (BSPP) or NPT instead of PT. A check valve (K) can be added to hold downstream pressure when the supply drops.

Flow for G-series units is published as curves, not as a single rated figure, so ask us to confirm sizing against your actual air demand before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

Airtac GC FRL Unit GC300C15MF1 FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated figure, so there is no one number we can quote. Tell us your inlet pressure and air demand and we will confirm the flow from the datasheet on request before you order.

In this code the M position specifies a manual drain on the filter bowl: condensate is emptied by hand, which suits lines checked routinely. Automatic (A) and differential-pressure (default) drains are available in the same size. With a manual-drain bowl the regulator range is 0.05-0.9 MPa (7-130 psi); automatic and differential-pressure versions adjust over 0.15-0.9 MPa (20-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C15MF1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C15MF1 and will confirm price, stock and lead time — usually within 7-8 hours.