AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC300C15MNK

The AirTAC GC FRL Unit GC300C15MNK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$104.72 $111.01Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC300C15MNK

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, plumbed in line so one order covers filtration, regulation and lubrication. This GC300C15MNK is the size 300 set with 1/2in PT ports and a reverse (check) valve fitted, which holds the downstream side against backflow. The filter bowl has a manual drain and a 40 um standard element, the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) in this manual-drain configuration, and the lubricator mists oil downstream. No gauge is fitted on this variant (N). Maximum inlet pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of ports, thread (PT standard, G and NPT as options), drain type, filtration grade and the reverse-valve (K) option shown here. Published flow figures are curves rather than a single rating, so ask us to confirm sizing or send the datasheet for your application.

Airtac GC FRL Unit GC300C15MNK Technical Specifications

ModelAirtac GC FRL Unit GC300C15MNK
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC300C15MNK

GC300G-series F.R.L. combination, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · See datasheet · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC300C15MNK Is Used

settings_input_component

Shared manifold on a multi-station cell

Conditioning air on a branch of a shared manifold in a multi-station assembly cell, where the check valve helps hold the regulated downstream side while neighbouring branches are vented or cycled.

engineering

Robotic palletizer gripper circuit

Supplying the vacuum generators and gripper cylinders on a robotic palletizer: filtered, regulated, lubricated air with the check valve holding the circuit against backflow between cycles.

local_shipping

Truck dock pneumatic door system

Preparing air for high-speed dock door actuators at a distribution center, with a 40 um element shielding the valves and oil mist extending cylinder service life.

Is the Airtac GC FRL Unit GC300C15MNK the Right Station?

Size 300 with 1/2in PT ports is the mid-range step in the GC line; move to 200, 400 or 600 as your flow and port requirements dictate. Choose the K (check valve) variant when you want the regulator setting held downstream and protected against backflow - for example on a branch that shares supply with other equipment. Manual drain suits attended installations; choose automatic or differential-pressure drain for unattended ones. The 40 um element is standard for general plant air; the 5 um (W) variant is the finer option. This variant has no gauge (N). PT is the standard thread; G (BSPP) and NPT are catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.

Airtac GC FRL Unit GC300C15MNK FAQ

Yes - on request. AirTAC publishes GC series flow as curves rather than a single rated figure, so we do not state one number here. Send us your application details and we will confirm sizing and provide the datasheet.

K means a reverse (check) valve is fitted, so the downstream side is held against backflow - useful when the set feeds a branch that must keep its regulated pressure while neighbouring equipment vents. The base GC300C15MN without K has no check valve.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC300C15MNK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC300C15MNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.