The AirTAC GC FRL Unit GC300C15MNW is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, plumbed in line so one order covers filtration, regulation and lubrication. This GC300C15MNW is the size 300 set with 1/2in PT ports and the fine 5 um filter element (W) instead of the 40 um standard. The filter bowl has a manual drain, the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) in this manual-drain configuration, and the lubricator mists oil downstream. No gauge is fitted on this variant (N). Maximum inlet pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of ports, thread (PT standard, G and NPT as options), drain type, and 40 um or 5 um filtration. Published flow figures are curves rather than a single rating, so ask us to confirm sizing or send the datasheet for your application.
| Model | Airtac GC FRL Unit GC300C15MNW |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
Supplying lab automation actuators and sample-handling cylinders where a 5 um element gives finer protection for the small pilot valves than standard 40 um plant filtration.
Conditioning air for pick-and-place modules on an electronics assembly line, with fine 5 um filtration ahead of the vacuum ejectors and precision cylinders, plus oil mist for actuator life.
Feeding air tools and actuators around an industrial paint booth area, where finer 5 um filtration supports cleaner downstream air ahead of a dedicated point-of-use dryer and filter set.
The W suffix is the key choice here: a 5 um element for finer particulate removal where sensitive valves, air bearings or instrumentation sit downstream, against the 40 um standard for general plant air. Size 300 with 1/2in PT ports is the mid-range step in the GC line - resize to 200, 400 or 600 per your flow and ports. Manual drain suits attended installations; automatic (A) or differential-pressure (default) drain suits unattended ones. This variant has no gauge (N) and no check valve. PT is the standard thread; G (BSPP) and NPT are catalogue options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
AirTAC publishes GC series flow as performance curves, not as a single rated number, so we do not quote one figure. Ask us to confirm sizing and we will send the datasheet curve for your pressure and flow point on request.
Choose W (5 um) when sensitive components such as precision pilot valves, ejectors or instrumentation sit downstream and need finer particulate removal. The standard 40 um element is normally sufficient for general plant air tools and cylinders.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.