The AirTAC GC FRL Unit GC300C15NK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC300C15NK is an AirTAC G-series three-unit F.R.L. combination - separate filter, regulator and lubricator - fitted with the K reverse/check valve. At size 300 with a 1/2 in. PT port, it filters to 40 um, regulates downstream pressure over 0.15-0.9 MPa (20-130 psi) with its differential-pressure drain, oils the air stream, and the check valve prevents backflow toward the supply side. The N code means no gauge is fitted; the bowls are polycarbonate for -5 to 70 C service.
This is a genuine AirTAC part. The GC series runs from sizes 200 to 600, with 5 um filtering (W), automatic or manual drains, gauges in MPa, psi or bar scales, G (BSPP) or NPT threads, and bracket mounting available. Maximum inlet pressure is 1.0 MPa (145 psi). Flow for the series is published as curves, not a single rating - ask us and we will confirm the datasheet figures for your line before you order.
| Model | Airtac GC FRL Unit GC300C15NK |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-C1 filter, GR300-C1 regulator and GL300-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · See datasheet · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-C1 |
| Build order | Filter → regulator → lubricator |
On a machining-line clamping fixture, the fitted reverse/check valve holds downstream pressure if the shop air supply dips, keeping the part securely clamped until the cycle finishes.
Keeps a small pneumatic press under steady regulated pressure, with the check valve blocking backflow on exhaust and the lubricator conditioning the ram cylinder over long production runs.
Runs quarter-turn pneumatic actuators on a plant floor: 40 um filtration ahead of the regulator, a stable setpoint backed by the K check valve through supply dips, and oil mist for the actuator seals.
This size 300 set has a 1/2 in. PT port; move to 400 or 600 for larger ports and more flow, or to 200 for tighter panels. The K code adds a reverse/check valve, useful when downstream pressure must not be lost to a supply dip - otherwise the drain is the differential-pressure default, with automatic (A) or manual (M) available to order. Filter grade is 40 um standard, 5 um with W. No gauge is fitted (N); round or square gauges in MPa, psi or bar scales can be specified. PT is the standard thread, with G (BSPP) and NPT as catalogue options. AirTAC publishes flow as curves, not a single rating, so let us confirm sizing against your flow and pressure requirements before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-C1 regulator with a GF300-C1 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than one rated number, so we do not state a figure here. Give us your flow and working pressure and we will confirm the sizing from the datasheet curves before you order.
K means a reverse/check valve is fitted. It blocks backflow from the downstream side toward the supply, so regulated pressure is held if the upstream air dips or is shut off - useful for clamps, chucks and holding circuits.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.