verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC400C10MC1

The AirTAC GC FRL Unit GC400C10MC1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$139.89 $147.05Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC400C10MC1

GC400C10MC1 is the three-piece AirTAC G-series F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator on one prepared-air line. This 400-size set is ported PT3/8 and keeps the standard 40 um filter element. The drain is the manual type, so condensate in the filter bowl is emptied by hand at intervals, and the regulator carries an external round pressure gauge with an MPa scale. Maximum inlet pressure is 1.0 MPa (145 psi); with the manual drain the regulator adjusts from 0.05-0.9 MPa (7-130 psi); the medium is compressed air and the working temperature range is -5 to 70 C (non-freezing). The filter and lubricator bowls on this 400 size are PC (polycarbonate).

This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and GC sets can be ordered with 40 um or 5 um filtration, differential-pressure, automatic or manual drains, embedded square gauges or external round gauges in MPa, psi or bar scales, G (BSPP) or NPT threads in place of the PT standard, and an optional mounting bracket. Flow is published as curves rather than a single rating, so contact us and we will confirm the datasheet figures on request.

Airtac GC FRL Unit GC400C10MC1 Technical Specifications

ModelAirtac GC FRL Unit GC400C10MC1
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC400C10MC1

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC400C10MC1 Is Used

build

Pneumatic press station

Air preparation for a bench-mounted pneumatic press, where the 40 um element handles general plant air, the manual drain suits a regularly attended station and the round MPa gauge gives the operator a clear setpoint readout.

factory

Bottling filler supply

Conditioned air for the cylinder bank of a bottling filler, combining filtration, a regulated supply pressure and oil-mist lubrication for the actuators on a single PT3/8 line.

handyman

Vehicle service bay

Feed for impact wrenches and air ratchets in a service bay: the lubricator mists oil to the tool motors, the regulator sets a consistent working pressure and the 40 um filter handles standard shop air.

Is the Airtac GC FRL Unit GC400C10MC1 the Right Station?

Here the choices are the 400 size with PT3/8 ports (step to 600 or 300 if your line differs), the standard 40 um element, and the manual drain, which suits duties where someone is already at the machine and can open the bowl drain periodically. The external round gauge reads MPa; the embedded square gauge and psi or bar scales are alternatives. PT is the standard thread, with G (BSPP) and NPT available as catalogue options, and a mounting bracket is optional. Flow in this series is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

Airtac GC FRL Unit GC400C10MC1 FAQ

AirTAC publishes G-series flow as curves across pressure conditions rather than a single rated figure, so we do not quote one number here. Send us your application details and we will confirm the datasheet flow figures on request.

The manual drain on this set means someone opens the filter bowl drain by hand to remove condensate, which suits attended stations. Automatic and differential-pressure drains remove the manual routine. Note the regulator range also follows the drain type: 0.05-0.9 MPa with manual drain versus 0.15-0.9 MPa with automatic or differential-pressure drain.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC400C10MC1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C10MC1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.