The AirTAC GC FRL Unit GC400C15AC1K is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC400C15AC1K is a genuine AirTAC G-series three-unit F.R.L. combination: separate air filter, pressure regulator and lubricator assembled as one set, with the trailing K adding a reverse (check) valve against backflow through the unit. The 400 size carries PT 1/2 in ports. This configuration is the 40 um standard filter grade, the automatic drain (A), which expels collected condensate on its own, and the round external gauge (C) with an MPa scale (1). The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) on this automatic-drain version. Maximum working pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing. The 400-size bowls are polycarbonate (PC).
This is a genuine AirTAC part. The G-series F.R.L. line spans 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, 40 um standard or 5 um (W) filtration, differential-pressure, automatic and manual drain variants, embedded square or external round gauges in MPa, psi or bar scales, and a K check-valve variant. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application.
| Model | Airtac GC FRL Unit GC400C15AC1K |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Feeds weld-fixture clamps that must stay closed through brief supply dips, with the check valve limiting backflow through the set and the round gauge showing the clamping pressure setting.
Conditions air for diverter gates, stoppers and lift-and-locate units along a conveyor system, giving the whole run one point of filtration, regulation, lubrication and backflow protection.
Serves air-fed equipment and actuated paint-kitchen valves in a finishing shop, with the automatic drain clearing condensate and the regulator holding the set pressure the booth was tuned to.
Pick this code over the plain GC400C15AC1 when you want the K reverse (check) valve fitted, blocking backflow through the set from the downstream side. Size 400 with PT 1/2 in ports fits half-inch plumbed lines; step to 200/300/600 as flow needs change. The A drain handles condensate automatically; differential-pressure (blank) and manual (M) drains are the alternative codes, and the 0.05-0.9 MPa adjust range applies to manual-drain versions versus 0.15-0.9 MPa here. This is the 40 um standard grade; choose W for 5 um. The round gauge reads in MPa; psi and bar scales and the embedded square gauge are other options. Thread is PT as the standard; G (BSPP) and NPT are catalogue options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
Yes, on request. Flow for G-series units is published as curves rather than a single rated figure, so we do not state one rated number. Give us your working pressure and consumption and we will confirm the match against the datasheet curves before you order.
Only the trailing K: the K version has a reverse (check) valve fitted so the downstream side is blocked from pushing back through the set, while GC400C15AC1 has no check valve. Ports, drain, filter grade and gauge are otherwise the same decode.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.