AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC400C15F1K

The AirTAC GC FRL Unit GC400C15F1K is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$151.24 $158.68Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC400C15F1K

The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator piped together as one set, so the supply is cleaned, held at a set pressure and oiled before it reaches cylinders, valves and air tools. This GC400C15F1K is the size 400 set with PT1/2 (1/2 inch) PT ports, standard 40 um filtration, a differential-pressure drain on the filter bowl, an external round pressure gauge scaled in MPa, and a reverse (check) valve fitted. Maximum working pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.15 to 0.9 MPa (20 to 130 psi), the temperature range is -5 to 70 C (non-freezing), and the filter bowl on size 400 is polycarbonate (PC).

This is a genuine AirTAC part from the GC range, which runs in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, PT (standard), G (BSPP) or NPT threads, differential-pressure, automatic or manual drains, 40 um or 5 um (W) filter elements, square or round gauges in MPa, psi or bar scales, and an optional reverse valve. AirTAC publishes flow as curves rather than a single rated figure, so send us your operating conditions and we will confirm sizing and datasheet figures on request.

Airtac GC FRL Unit GC400C15F1K Technical Specifications

ModelAirtac GC FRL Unit GC400C15F1K
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC400C15F1K

GC400G-series F.R.L. combination, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · See datasheet · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-C1
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC400C15F1K Is Used

precision_manufacturing

Weld-clamp cylinders on an automotive body line

Filtered, regulated and lubricated air at the line drop keeps spot-weld clamp cylinders on a body-in-white line actuating consistently across shifts; this PT1/2 size 400 set sits at the drop feeding the clamp manifold.

conveyor_belt

Carton-sealer and case-packer cylinders

On a packaging line, the F.R.L. set conditions the air feeding carton-sealer and case-packer cylinders, protecting valves from dirt and water while keeping lubrication mist to the actuators.

build

Assembly-bench impact wrenches and air tools

At a maintenance or assembly bench, the three units give hand-held impact wrenches, grinders and ratchets clean, pressure-stabilised, oiled supply through the 1/2-inch drop.

Is the Airtac GC FRL Unit GC400C15F1K the Right Station?

Step up to size 400 with PT1/2 ports when the machine supply is 1/2-inch mains and the duty sits between the compact 300 set and the larger 600 set - select by flow first and let the port follow the pipework. This configuration already fixes several choices: 40 um standard filtration, a differential-pressure drain (order A for automatic or M for manual instead), a round MPa gauge (an embedded square gauge, or psi/bar scales, are alternatives), and the K reverse/check valve - drop the K if you do not want it. Thread is PT as standard, with G (BSPP) and NPT available as orderable suffixes, and a mounting bracket is optional. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.

Airtac GC FRL Unit GC400C15F1K FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote one figure here. Tell us your operating pressure and air demand and we will confirm the sizing from the datasheet on request.

K is the catalogue code for a reverse (check) valve fitted to this set. The same combination ordered without the K gives you the identical filter-regulator-lubricator unit without the check valve.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC400C15F1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC400C15F1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.