The AirTAC GC FRL Unit GC400C15MF1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC400C15MF1 is a three-piece F.R.L. combination: separate air filter, pressure regulator and lubricator working in line. This 400-size unit takes PT1/2 ports, drains its filter bowl manually, filters to the standard 40 um grade, and reads regulated pressure on an embedded square gauge with an MPa scale.
This is a genuine AirTAC part from the G series, spanning 200, 300, 400 and 600 sizes with drain-type, filter-grade, gauge-style and thread options (PT standard, G and NPT to order). Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.
| Model | Airtac GC FRL Unit GC400C15MF1 |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Mounted at the cabinet of a palletiser cell, this set feeds the gripper and pusher cylinders with filtered, regulated, lubricated air, the embedded square gauge giving the operator a quick pressure check at the panel.
Installed on a workshop drop feeding assembly benches and air tools, the unit removes water and debris at 40 um, sets a stable working pressure, and oils the tools, with the bowl emptied by hand during housekeeping rounds.
Used at a fixture setup station where technicians tune clamping pressures between jobs, the separate regulator and its square MPa gauge let each fixture be set repeatably before it goes onto the production machine.
GC400C15MF1 is the straightforward 400-size F.R.L. set on PT1/2: standard 40 um filtration, manual bowl drain and the embedded square gauge in MPa. Choose it when a compact built-in gauge is preferred over the external round type; psi and bar scales are also available. For lighter demand use the 300 size on 3/8"; for heavier lines move to the 600 size on 3/4" or 1".
If the unit sits where no one walks a drain round, re-specify with automatic (A) or differential-pressure drain instead of M. Thread is PT as standard with G (BSPP) and NPT as catalogue options. Flow is published only as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
We do not quote one, because AirTAC publishes G-series flow as characteristic curves rather than a single rated figure. Send us your operating pressure and air consumption and we will confirm the sizing and datasheet details for this 400-size, PT1/2 set on request.
GC is a three-unit combination: a separate filter, a separate regulator and a separate lubricator, so you get filtration, regulation and oil misting. A GFR is a two-function filter-regulator with no lubricator, and a GFC pairs that filter-regulator with a lubricator in a two-piece set.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.