The AirTAC GC FRL Unit GC400C15MF1K is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC400C15MF1K is an AirTAC GC-series three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one 400-size set for compressed air. The standard connection is PT1/2 (1/2 in PT). The filter unit drains manually and carries the standard 40 um element in a polycarbonate bowl, and the regulator adjusts from 0.05-0.9 MPa (7-130 psi) in this manual-drain configuration, with an embedded square gauge reading in MPa. A reverse (check) valve is fitted in this version.
This is a genuine AirTAC part, rated for a maximum working pressure of 1.0 MPa (145 psi) and -5 to 70 C (non-freezing). The G series spans 200, 300, 400 and 600 sizes, with port steps, G (BSPP) and NPT thread options to order, drain choices, a 5 um (W) filtration option, and psi or bar gauge scales. AirTAC publishes flow as curves rather than a single rating, so we confirm datasheet and flow figures for your application on request.
| Model | Airtac GC FRL Unit GC400C15MF1K |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-C1 filter, GR400-C1 regulator and GL400-C1 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · See datasheet · 40 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-C1 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to the clamp and weld-gun cylinders along a body trim line, with the check valve blocking reverse flow if the supply side is shut down.
Prepares the air feeding tool-changer cylinders, work clamps and air-blast nozzles on a machining center; the 40 um element keeps debris out of the machine's valves and the lubricator supplies oil mist to the cylinders.
Supplies the diverters, pushers and stopper cylinders on a packaging conveyor line, with the embedded square MPa gauge giving operators a set point they can read at the machine.
Start with the port step: the 400 size carries 1/2 in PT ports, and stepping to 200, 300 or 600 changes both the connection and the flow window, so size against the demand of the line. Drain type is the next choice: the M in this code means you drain the filter bowl by hand on a schedule, while automatic (A) and the differential-pressure series default discharge condensate without manual attention - useful at hard-to-reach points. Filtration here is the standard 40 um; the W option gives 5 um. The square gauge reads in MPa, with psi (2) and bar (3) scales available. Thread is PT as standard unless you order the G (BSPP) or NPT variant. Because AirTAC publishes flow as curves, not a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-C1 regulator with a GF400-C1 filter on that branch.
AirTAC does not publish a single rated flow figure for the 400 size; flow is given as performance curves. We therefore do not quote a number that is not in the datasheet. Send us your line pressure and air demand and we will confirm the sizing from the datasheet on request.
M in the code means the filter bowl is drained by hand, so the drain point needs to be accessible on a maintenance schedule. AirTAC also offers automatic (A) drains and the differential-pressure drain that is the series default, both of which discharge condensate without someone opening the valve. The drain sits on the filter unit of this three-piece set; the regulator and lubricator do not carry it.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.