The AirTAC Airtac GFC Combination Unit GFC200C06C1K is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series combines a filter-regulator and a lubricator in one matched two-piece set for filtration, regulation and oil-mist lubrication of a compressed-air line. This GFC200C06C1K is the size 200 frame with PT1/8 (1/8 in.) ports, the standard 40 um filter element, differential-pressure drains and an external round gauge on the regulator with MPa scale. The K option adds a reverse/check valve, so downstream pressure is held if the supply side drops - a practical safeguard for clamping and holding circuits. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with this drain type, and the working temperature range is -5 to 70 C.
This is a genuine AirTAC part. The G range is available in sizes 200, 300, 400 and 600, with 40 um or 5 um elements, differential-pressure, automatic or manual drains, embedded square or external round gauges, and PT, G (BSPP) or NPT threads. Capacity is published as flow curves, so we confirm datasheet figures on request.
| Model | Airtac GFC Combination Unit GFC200C06C1K |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
Feeding clamp cylinders on a milling or turning fixture, the regulator sets the clamp force and the check valve holds the clamped side if shop air is interrupted mid-cycle.
Supplying the gate cylinders that steer parcels between lanes, the set cleans the air, fixes the switching pressure shown on the gauge and lubricates the actuators, while the check valve keeps the gate circuit loaded.
Mounted at the drop to a bottle-capping head, the two-unit set conditions that station's air - 40 um filtration, regulated pressure and oil mist - cycle after cycle.
Size 200 with PT1/8 ports is the entry step of the G range (200, 300, 400 and 600); each step up raises port size and capacity, but since capacity is published as curves rather than one rated figure, ask us to confirm sizing against your application before ordering. This code adds the K reverse/check valve for circuits that must hold pressure through supply dips. Other family choices are drain type (differential-pressure, automatic or manual; manual drain widens the regulation range to 0.05-0.9 MPa / 7-130 psi), the standard 40 um element or the 5 um option, the gauge scale (MPa here; psi or bar available), and G (BSPP) or NPT threads in place of the standard PT.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes G-series capacity as flow curves rather than a single rated figure, so no rated number is stated here. Send your operating pressure, downstream demand and acceptable pressure drop, and we will confirm the datasheet curve on request.
PT is the standard thread on this model; G (BSPP) and NPT are catalogue options you can order instead. Choose whichever matches the fittings already on your machine, and state it when ordering so the ports arrive threaded to match your pipework.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.