The AirTAC Airtac GFC Combination Unit GFC200C06F1K is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC200C06F1K is a genuine AirTAC G-series two-unit set that combines a filter regulator and a lubricator, delivering filtered, regulated and lubricated air from one assembly. This size 200 configuration has a PT1/8 port for compact branch lines, the standard 40 um filter element, differential-pressure drains on the PC bowls, the embedded square MPa gauge, and a fitted reverse (check) valve. Regulation range with differential-pressure drain is 0.15-0.9 MPa (20-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi) and a -5 to 70 C (non-freezing) operating range.
The G-series is available in 200, 300, 400 and 600 sizes with ports from 1/8 inch to 1 inch, in PT (standard), G (BSPP) or NPT threads, and with drain, filter-grade, gauge and reverse-valve options. Flow is published as curves rather than a single rating, so we confirm datasheet figures on request.
| Model | Airtac GFC Combination Unit GFC200C06F1K |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
Filtered, regulated and oiled air ahead of a solenoid-valve manifold on an automated fixture circuit, with the check valve holding supply in the set.
Air preparation for clamp and sensor actuators distributed across the stations of a palletised assembly line, fed through one PT1/8 drop.
A workshop air drop feeding lubricated hand tools and test rigs, giving maintenance staff a set, gauge-monitored working pressure.
Size first: 200 is the compact G-series frame with a PT1/8 port here; 300, 400 and 600 step up in port and flow. Drain type is decodable: differential-pressure (this unit), automatic (A) or manual (M). Filtration is the standard 40 um element; order W for 5 um. The K in this code adds the reverse (check) valve; omit it if your circuit already handles backflow. The embedded square gauge reads MPa, with round gauges and psi or bar scales available, and PT thread is standard alongside G (BSPP) and NPT options.
Since flow is published as curves, not a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
Flow for the GFC series is published by AirTAC as curves rather than a single rated number, so there is no figure to state here. Share your pressure and demand and we will confirm sizing from the datasheet on request.
K indicates a reverse (check) valve is fitted, so the blank version is the same set without it. Together with drain type, filter grade and gauge choices, that makes the K option one of the real decode decisions when specifying a GFC200 set.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.