The AirTAC Airtac GFC Combination Unit GFC200C06F1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC200C06F1W is a genuine AirTAC G-series two-unit set combining a filter regulator with a lubricator, so one assembly filters, regulates and lubricates the compressed air. This size 200 configuration has a PT1/8 port for compact branch lines, the finer 5 um filter element in place of the standard 40 um grade, differential-pressure drains on the PC bowls, and the embedded square gauge reading pressure in MPa. Regulation range with differential-pressure drain is 0.15-0.9 MPa (20-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi) and a -5 to 70 C (non-freezing) operating range.
The G-series spans 200, 300, 400 and 600 sizes with ports from 1/8 inch to 1 inch, in PT (standard), G (BSPP) or NPT threads, plus drain, filter-grade, gauge and reverse-valve options. Flow is published as curves rather than a single rated figure, so we confirm datasheet numbers on request.
| Model | Airtac GFC Combination Unit GFC200C06F1W |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
Fine-filtered, regulated and oiled air to air-gauging probes and jet sensors on a quality-check station, where cleaner supply matters.
Air preparation for the grippers, cutters and blowoff nozzles on a wire cutting and stripping machine, keeping valves free of coarse particles.
A stable, gauge-monitored air supply to the clamps and load cylinders of a small pneumatic test rig, with the 5 um element guarding precision components.
Pick the size for your pipe and duty: 200 with its PT1/8 port is the compact choice, and 300 to 600 increase port and flow. Drain options are differential-pressure (as here), automatic (A) or manual (M). The W in this code selects the 5 um element where the standard 40 um grade is not fine enough; keep 40 um for general supply. The embedded square gauge shows MPa, with external round gauges and psi or bar scales as catalogue choices, and PT thread is standard with G (BSPP) or NPT to order.
Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes GFC flow performance as curves, so there is no single rated-flow figure we can state. Send us your line pressure and consumption and we will confirm the sizing from the datasheet on request.
W fits the optional 5 um filter element instead of the standard 40 um grade, which suits circuits feeding sensitive valves, sensors or instruments; general cylinder supply is usually fine at 40 um. Drain type, gauge style and thread are further decodable choices on the same frame.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.