The AirTAC GFC Combination Unit GFC200C06MF1K is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC family is a two-unit set: a filter-regulator plus a lubricator, so one connection point removes water and particulate from compressed air, holds a steady set pressure and meters oil mist to the tools and cylinders downstream. This 200-size set is ported PT1/8, uses the standard 40 um filter element and a manual drain (the filter bowl is drained by hand), and reads pressure on the embedded square gauge scaled in MPa. The trailing K means a reverse (check) valve is fitted. With the manual drain the regulator adjusts 0.05-0.9 MPa (7-130 psi). Maximum inlet pressure is 1.0 MPa (145 psi) and the working range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The G series runs in 200, 300, 400 and 600 sizes, from 1/8 in to 1 in ports, with differential-pressure, automatic or manual drains, 40 um standard or 5 um fine filtration, embedded square or external round gauges in MPa, psi or bar scales, and PT, G (BSPP) or NPT threads. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for this model on request.
| Model | Airtac GFC Combination Unit GFC200C06MF1K |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
Feeds impact wrenches and air ratchets at a commercial-vehicle workshop; the regulator holds the torque-critical pressure and the lubricator keeps the tool motors oiled between services.
Supplies the gripper and cylinder group on a robotic pick-and-place station, where the fitted check valve is part of the circuit design and the square gauge gives operators a fixed setpoint readout.
Conditions the air feeding pilot solenoid valves on a small process skid: filtered, regulated and oiled pilot air at one pressure, drained by hand during scheduled rounds.
Decodable choices on this family: the 200 size steps up to PT1/4 (08), PT3/8 (10) and larger ports as your air demand grows, so size the port to the supply line. Drains come as differential-pressure (standard), automatic (A) or manual (M, as here); the manual-drain regulator range is 0.05-0.9 MPa (7-130 psi). Filtration is the 40 um standard element on this code, with 5 um (W) available. The gauge is the embedded square type, MPa scale; an external round gauge and psi/bar scales are the alternatives. The K suffix fits a reverse (check) valve on this version - order the code without K if your circuit does not need one. PT is the standard thread; G and NPT are order options.
Because flow for this series is published as curves and not as a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes G-series capacity as flow curves rather than a single rated figure, so there is no single number to quote here. Share your line pressure and consumption and we will confirm the datasheet curve for this model on request.
K means a reverse (check) valve is fitted on this set. The same configuration without K - for example GFC200C06MF1 - has none. It is a straight decode choice, so order the suffix your circuit calls for and we can confirm details on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.