The AirTAC GFC Combination Unit GFC200C06N is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC200C06N is an AirTAC G-series two-unit air-preparation set: a filter-regulator and a lubricator paired as one assembly, so a single mounting filters, regulates and lubricates the compressed air. This 200-size configuration is threaded PT1/8, uses the standard 40 um filter element, drains its bowl by differential pressure and is supplied without a gauge.
This is a genuine AirTAC part in the 200 frame of a family that also steps through 300, 400 and 600 sizes. Max working pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with the differential-pressure drain, and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than one rated figure - ask us and we will confirm the datasheet numbers.
| Model | Airtac GFC Combination Unit GFC200C06N |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
Feeding filtered, regulated and lubricated air to the control valves and cylinders of a carton-forming and taping machine from a central 1/8 in take-off.
Preparing air for diverter and stopper cylinders along a distribution-centre conveyor line, with differential-pressure draining handling condensate between shifts.
Conditioning the air feeding clutch and counterbalance circuits on a small mechanical press in a job-shop environment, all from one compact two-unit set.
The 200 size with PT1/8 ports fits compact branch take-offs; move up to 300, 400 or 600 when the line demands larger ports and more flow. The differential-pressure drain on this model needs no routine draining attention, while manual (M) and automatic (A) drain bowls are also decodable choices. The standard 40 um element suits general plant air; specify W for the 5 um grade if downstream components are finer. A gauge can be added for visual setpoint control, and G (BSPP) or NPT threads are catalogue options alongside the standard PT. Flow appears only as published curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes flow for the G-series as curves rather than a single rated figure, so there is no one number to quote. Send us your required flow and working pressure and we will confirm the datasheet curve for this set before you place the order.
This model carries the 40 um standard element, which suits general plant air feeding cylinders and control valves. If the downstream circuit includes finer pilot valves, air bearings or instrumentation, order the W variant with the 5 um element instead. Both grades are available across the GFC family.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.