The AirTAC GFC Combination Unit GFC200C08C1 is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC family pairs a filter-regulator and a lubricator in one two-unit set: it strips water and particulate from compressed air, holds a set downstream pressure, and adds oil mist for the equipment fed from the outlet. This configuration is size 200 with PT1/4 ports, the standard 40 um element, differential-pressure bowl draining, and the optional external round pressure gauge with an MPa scale (C1). Maximum inlet pressure is 1.0 MPa (145 psi); with differential-pressure draining the regulation range is 0.15-0.9 MPa (20-130 psi); the set runs from -5 to 70 C, non-freezing. At size 200 the bowls are PC (polycarbonate).
This is a genuine AirTAC part. The G series spans sizes 200 to 600 with ports from 1/8 in to 1 in, and each position of the code can be re-ordered: drain type (differential-pressure, automatic A or manual M), 5 um (W) or standard 40 um element, embedded square gauge or external round gauge in MPa, psi or bar scales, PT, G (BSPP) or NPT thread, and bracket option. Flow is published as curves, not a single rating, so we confirm the datasheet and sizing for your application on request.
| Model | Airtac GFC Combination Unit GFC200C08C1 |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
A carton-sealing or wrapping machine with pneumatic fold and push cylinders: filtered, regulated and lubricated air at a readable setpoint, with the MPa gauge visible on the machine frame for operator checks.
Pusher and stopper cylinders along a conveyor line: the 1/4 in port matches typical branch take-offs, and the lubricator keeps wear parts on the line fed with oil mist over long shifts.
Quarter-turn pneumatic actuators on process valves: the regulator holds a steady actuator pressure shown on the round MPa gauge, and the 40 um element keeps debris out of the actuator supply.
Within the G series, step up from size 200 (PT1/4 here) to 300, 400 or 600 when your circuit needs a larger port and more flow. Drain choice for the filter bowl is differential-pressure (the default, as here), automatic (A) or manual (M); note that the regulation range depends on drain type: 0.15-0.9 MPa with auto or differential draining, 0.05-0.9 MPa with manual. Filter grade is 40 um standard, 5 um with W. For pressure indication you can keep the embedded square gauge, select the external round gauge with an MPa, psi or bar scale (C1 here is round, MPa), or delete the gauge with N. Thread is PT as standard, with G (BSPP) and NPT orderable as catalogue options; J deletes the bracket.
Flow figures are published as curves, not a single rated number, so send us your line pressure and required flow and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes G-series flow as performance curves rather than one rated figure, so we do not quote a single l/min or SCFM number here. Tell us your line pressure and required flow and we will confirm the correct size from the datasheet on request.
C selects the optional external round pressure gauge and 1 sets its scale to MPa. Omitting these letters leaves the embedded square gauge; psi (2) and bar (3) scales can also be ordered. The remaining blank positions mean PT thread, differential-pressure draining, standard 40 um element, no check valve and bracket included.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.